How To Fix OIUCW595 - Unable to Insert in GCTA table. SUBRC=&1


SAP Error Message - Details

  • Message type: E = Error

  • Message class: OIUCW - PRA Payment Processing modules

  • Message number: 595

  • Message text: Unable to Insert in GCTA table. SUBRC=&1

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message OIUCW595 - Unable to Insert in GCTA table. SUBRC=&1 ?

    The SAP error message OIUCW595, which states "Unable to Insert in GCTA table. SUBRC=&1," typically occurs in the context of the SAP Oil and Gas (O&G) module, particularly when dealing with the GCTA (Gas Contract Table Archive) table. This error indicates that there was an issue when trying to insert a record into the GCTA table, and the SUBRC (sub-return code) provides additional information about the nature of the error.

    Possible Causes:

    1. Data Integrity Issues: The data being inserted may violate constraints or rules defined for the GCTA table, such as primary key violations, foreign key constraints, or data type mismatches.
    2. Database Locking: The table may be locked by another transaction, preventing the insert operation from completing.
    3. Authorization Issues: The user attempting the insert may not have the necessary authorizations to perform the operation on the GCTA table.
    4. Technical Issues: There may be underlying technical issues, such as database connectivity problems or issues with the SAP system itself.
    5. Configuration Issues: Incorrect configuration settings in the O&G module or related areas may lead to this error.

    Solutions:

    1. Check Data Validity: Review the data being inserted to ensure it meets all the requirements for the GCTA table. Look for any missing or incorrect fields.
    2. Check for Locks: Use transaction codes like SM12 to check for any locks on the GCTA table. If there are locks, you may need to wait for the other transaction to complete or resolve the locking issue.
    3. Review Authorizations: Ensure that the user has the necessary authorizations to perform the insert operation. You can check this using transaction SU53 or by consulting with your security team.
    4. Analyze the SUBRC Code: The SUBRC value can provide specific information about the error. You can look up the meaning of the specific SUBRC code in SAP documentation or consult with your technical team.
    5. Check System Logs: Review the system logs (transaction SLG1) for any additional error messages or warnings that may provide more context about the issue.
    6. Consult SAP Notes: Search for relevant SAP Notes that may address this specific error. SAP Notes often contain solutions or workarounds for known issues.
    7. Technical Support: If the issue persists, consider reaching out to SAP support or your internal IT team for further assistance.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as SE11 (Data Dictionary), SE37 (Function Module), and SE80 (Object Navigator) to investigate the GCTA table and related function modules.
    • Documentation: Review SAP documentation related to the Oil and Gas module for any specific guidelines or best practices regarding the GCTA table.
    • Testing: If possible, replicate the issue in a development or test environment to better understand the cause without affecting production data.

    By following these steps, you should be able to diagnose and resolve the OIUCW595 error effectively.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.