Do you have any question about this error?
Message type: E = Error
Message class: OIUCA - E&P Contract Alloaction
Message number: 004
Message text: Measurement Point and chained network cannot be at the Plant level.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUCA004
- Measurement Point and chained network cannot be at the Plant level. ?The SAP error message OIUCA004 indicates that there is an issue with the configuration of measurement points and chained networks in the context of plant-level operations. This error typically arises in the SAP Oil and Gas (OIL) module, particularly when dealing with measurement points that are incorrectly set up in relation to the plant hierarchy.
Cause:
The error occurs when:
- A measurement point is defined at the plant level, but it is being used in a context where it is expected to be at a different level (e.g., at the operational level or within a specific network).
- There is a mismatch between the measurement point and the network configuration, particularly if the measurement point is part of a chained network that is not properly aligned with the plant structure.
Solution:
To resolve the OIUCA004 error, you can take the following steps:
Check Measurement Point Configuration:
- Navigate to the configuration of the measurement point in the SAP system.
- Ensure that the measurement point is correctly assigned to the appropriate level (e.g., operational level) rather than the plant level.
Review Chained Network Setup:
- Verify the configuration of the chained network to ensure that it is correctly set up and that the measurement points are appropriately linked.
- Ensure that the measurement points are not directly associated with the plant level if they are intended to be part of a network.
Adjust Hierarchy Levels:
- If necessary, adjust the hierarchy levels of the measurement points and networks to ensure they align with the expected structure in SAP.
- This may involve reassigning measurement points to different operational levels or modifying the network configuration.
Consult Documentation:
- Refer to SAP documentation or help resources specific to the Oil and Gas module for additional guidance on measurement point and network configurations.
Testing:
- After making the necessary adjustments, test the configuration to ensure that the error no longer occurs and that the measurement points and networks function as intended.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a consultant with expertise in the Oil and Gas module for further assistance.
Get instant SAP help. Start your 7-day free trial now.
OIUCA003
Production Date must be last day of month for monthly Frequency Code.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUCA002
GP Entitlement Allocation percent must be between 0 and 100.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUCA005
Owner is not valid for DOI / & for production date.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUCA006
Material must be NGL(Major Product Code 4) at the plant level.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...