Do you have any question about this error?
Message type: E = Error
Message class: OIJ_EL - OIL TSW: Messages for TSW Execution Layer
Message number: 121
Message text: Uom &1 not found in internal table T_TKT_I_O2
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIJ_EL121
- Uom &1 not found in internal table T_TKT_I_O2 ?The SAP error message OIJ_EL121, which states "Uom &1 not found in internal table T_TKT_I_O2," typically occurs in the context of the SAP Oil and Gas (OIJ) module. This error indicates that the unit of measure (UoM) specified in the transaction is not found in the internal table that the system is using to validate or process the data.
Cause:
- Invalid Unit of Measure: The UoM being referenced (denoted by &1 in the error message) does not exist in the system or is not correctly defined in the relevant configuration.
- Missing Configuration: The unit of measure may not be included in the internal table T_TKT_I_O2, which is used for ticket processing in the OIJ module.
- Data Entry Error: There may be a typographical error in the UoM entered by the user.
- Master Data Issues: The master data for the material or product being processed may not have the correct UoM assigned.
Solution:
- Check UoM Definition: Verify that the UoM exists in the system. You can do this by navigating to the relevant configuration settings in SAP (Transaction Code: CUNI for unit of measure maintenance).
- Update Internal Table: If the UoM is valid but not included in the internal table T_TKT_I_O2, you may need to update the configuration or the internal table to include the necessary UoM.
- Correct Data Entry: Ensure that the UoM entered in the transaction is correct and matches the defined UoMs in the system.
- Review Master Data: Check the master data for the relevant materials or products to ensure that the correct UoM is assigned.
- Consult Documentation: Review any relevant SAP documentation or notes related to the OIJ module for additional guidance on UoM issues.
Related Information:
By following these steps, you should be able to identify and resolve the issue related to the OIJ_EL121 error message.
Get instant SAP help. Start your 7-day free trial now.
OIJ_EL120
Actual nomination UoM & not in ticket table of alternative UoM found.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIJ_EL119
Unactualized ticket exists for nomination item. Process blocked.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIJ_EL122
Error during nomination status update
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIJ_EL123
Exception &1 from OIB_MATERIAL_UNIT_CONVERSION
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.