Message type: E = Error
Message class: OC - IS-Oil: BDRP Bulk Distribution Requirement Planning messages
Message number: 537
Message text: Reference type & has no LVCC set - request cancelled
You asked the system to clear the LVCC entries for the current
<GL:storage_object>storage object</> and reinstate a reference to the
LVCC entries defined at the <GL:storage_object_type>storage object type
</> level. However, the system cannot find any LVCC entries for
storage object type &V1&.
The request is cancelled by the system.
If you wantto delete the LVCC entries for this object use the delete
function.
Error message extract from SAP system. Copyright SAP SE.
OC537
- Reference type & has no LVCC set - request cancelled ?The SAP error message OC537, which states "Reference type & has no LVCC set - request cancelled," typically occurs in the context of SAP's Logistics Execution (LE) or Warehouse Management (WM) modules. This error indicates that a reference type (such as a delivery, transfer order, or other logistics document) does not have a "Logical Volume Control Code" (LVCC) set, which is necessary for processing certain operations.
Cause: Missing LVCC Configuration: The reference type in question has not been properly configured to include a Logical Volume Control Code. This can happen if the necessary settings were not defined during system configuration. Data Inconsistencies: There may be inconsistencies or missing data in the master data or transaction data related to the reference type. Custom Development: If there are custom developments or enhancements in the system, they may not be handling the LVCC correctly.
Solution: Check Configuration: Go to the configuration settings for the reference type in question. This can
Get instant SAP help. Sign up for our Free Essentials Plan.
OC529
To delete an item, please place the cursor on a valid table entry
What causes this issue? A delete item instruction was issued, but the cursor was not placed on an item.System Response No deletion occurs.How to fix...
OC524
Unspecified error when reading LVCC item table for set number &
What causes this issue? An unknown return code was encountered when processing user input in the <GL:linear/volumetric_conversion_constant> lin...
OC544
Linear input value is less than the lowest LV constant
What causes this issue? The linear input value that you have input is less than the lowest <GL:linear/volumetric_conversion_set>linear/ volumet...
OC545
Linear input value is greater than highest LV constant
What causes this issue? The linear input value that you have input is greater than the highest <GL:linear/volumetric_conversion_set>linear/ vol...
Click on this link to search all SAP messages.