Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 178
Message text: Dimension "heating value (molar)" not found in Table T006D
There is no "heating value (molar)" dimension defined in Table T006D.
The Quantity Conversion Interface (QCI) stops processing.
Maintain that dimension in Table T006D (Transaction CUNI). Use the
entries delivered with IS OIL template client 065 as a blueprint for
this activity.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3178
- Dimension "heating value (molar)" not found in Table T006D ?The SAP error message O3178 indicates that the system is unable to find the specified dimension, in this case, "heating value (molar)," in the table T006D. This table is used in SAP to store unit of measure (UoM) dimensions, and the error typically arises when there is a missing or incorrectly configured entry for the specified dimension.
Cause:
- Missing Entry: The dimension "heating value (molar)" may not be defined in the T006D table.
- Incorrect Configuration: There might be a configuration issue where the dimension is not properly linked to the relevant material or process.
- Data Migration Issues: If data was migrated from another system, the dimension may not have been included or correctly mapped.
- Custom Development: If there are custom developments or enhancements, they may not be correctly referencing the dimension.
Solution:
Check T006D Table:
- Use transaction code SE16 or SE11 to view the T006D table.
- Look for the entry corresponding to "heating value (molar)." If it is missing, you will need to create it.
Create Missing Dimension:
- If the dimension is not found, you can create it using transaction code CUNI (Unit of Measure Conversion).
- Ensure that you define the dimension correctly, including the appropriate unit of measure and any necessary attributes.
Review Configuration:
- Check the configuration settings related to units of measure in the SAP system.
- Ensure that all necessary dimensions are defined and linked to the relevant materials or processes.
Data Consistency Check:
- If the error occurred after a data migration, perform a consistency check to ensure that all necessary data has been migrated correctly.
Consult Documentation:
- Review SAP documentation or notes related to unit of measure dimensions for any specific requirements or updates.
Contact SAP Support:
- If the issue persists after checking the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to resolve the error message O3178 and ensure that the dimension "heating value (molar)" is correctly defined in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
O3177
Incorrect dimension: enter a unit of measure with dimension density
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3176
Incorrect dimension: enter a dimensionless unit of measure
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3179
Dimension "heating value (mass)" not found in Table T006D
What causes this issue? There is no "heating value (mass)" dimension defined in Table T006D.System Response The Quantity Conversion Interf...
O3180
Enter a unit of measure with dimension heating value (volume)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...