Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 081
Message text: The quantity table contains an entry with an invalid unit of measure
The Quantity Conversion Interface (QCI) calculates a set of target
quantities based on a source quantity and source UoM and a set of
quantity conversion parameters (density, heating value, reference
pressures and temperatures) for a given list of target units of
measure. Before the calculation can take place, the set of target UoM is
checked. This check failed, since at least one of the target UoM in the
internal table is not defined .
The system stops processing.
Contact your system administrator.
The problem is caused by an incorrect call of function
OIB_QCI_QUANTITY_CONTROL. Note the transaction or process for which the
error occurs and either change your program or contact SAP if the error
occurs in a standard SAP program.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3081
- The quantity table contains an entry with an invalid unit of measure ?The SAP error message O3081, which states "The quantity table contains an entry with an invalid unit of measure," typically occurs when there is a mismatch or an invalid entry in the unit of measure (UoM) for a quantity in a transaction or document. This can happen in various contexts, such as during the creation of purchase orders, sales orders, or inventory management.
Causes:
- Invalid Unit of Measure: The unit of measure used in the transaction does not exist in the system or is not valid for the material or item being processed.
- Configuration Issues: The unit of measure may not be properly configured in the material master or in the relevant settings for the transaction.
- Data Entry Errors: Manual entry of the unit of measure may have been incorrect, leading to the error.
- Missing Conversion Factors: If the unit of measure is valid but lacks the necessary conversion factors to other units, it can lead to this error.
- Inconsistent UoM in Master Data: The unit of measure in the transaction may not match the unit of measure defined in the material master.
Solutions:
Check the Unit of Measure:
- Verify that the unit of measure used in the transaction is valid and exists in the system.
- You can check this in the SAP transaction code
CUNI
(Unit of Measure Conversion) or by looking at the material master data.Review Material Master Data:
- Go to the material master (transaction code
MM03
) and check the unit of measure settings for the material in question.- Ensure that the base unit of measure and any alternative units of measure are correctly defined.
Correct Data Entry:
- If the error is due to manual entry, correct the unit of measure in the transaction and try again.
Check Configuration:
- Ensure that the unit of measure is properly configured in the relevant customizing settings. This can be done through transaction code
SPRO
and navigating to the relevant sections for material management or sales and distribution.Conversion Factors:
- If applicable, ensure that conversion factors between different units of measure are defined correctly in the system.
Consult Documentation:
- Review SAP documentation or help resources for specific guidance related to the error message and the context in which it occurs.
Related Information:
MM03
- Display Material MasterCUNI
- Maintain Units of MeasureSPRO
- Customizing Implementation GuideBy following these steps, you should be able to identify the cause of the O3081 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
O3080
Enter a numeric value
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3079
Unrealistic BSW % value greater than 10%
What causes this issue? You have entered a Base Sediment & Water (BSW) fraction for a quantity converison which is greater than 10% . This is an ...
O3082
The material/plant/storage location/batch/date range does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3083
Quantity Conversion Interface: More than & parameters for FMTYTP &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.