Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 048
Message text: Dimension "temperature" is missing in Table T006D
There is no "temperature" dimension in Table T006D.
System response: Quantity Conversion Interface (QCI) processing is
terminated.
Maintain the "temperature" dimension in Table T006D (Transaction CUNI).
Use the entries delivered with IS OIL template client 065 as a blueprint
for this activity.
Error message extract from SAP system. Copyright SAP SE.
O3048
- Dimension "temperature" is missing in Table T006D ?The SAP error message O3048 indicates that a specific dimension, in this case, "temperature," is missing in the table T006D, which is used for storing unit of measure (UoM) information in SAP. This error typically arises when there is an attempt to use a unit of measure that has not been defined or is not properly configured in the system.
Cause:
- Missing Configuration: The dimension "temperature" has not been defined in the T006D table, which means that the system does not recognize it as a valid unit of measure.
- Incorrect Data Entry: There may be an attempt to use a unit of measure related to temperature that is not set up in the system.
- Custom Development: If there are custom developments or enhancements that reference the temperature dimension, they may not be properly configured.
Solution:
Check T006D Table:
- Go to transaction code SE16 or SE11 and check the T006D table to see if the "temperature" dimension is present.
- If it is missing, you will need to add it.
Add Missing Dimension:
- If you have the necessary authorizations, you can add the missing dimension directly in the T006D table.
- You may need to define the unit of measure for temperature (e.g., Celsius, Fahrenheit) in the T006 table as well.
Configuration in SPRO:
- Navigate to the SAP Customizing Implementation Guide (SPRO).
- Go to Logistics - General > Basic Settings > Units of Measure > Define Units of Measure.
- Here, you can define new units of measure and ensure that the temperature dimension is included.
Check for Custom Code:
- If there are any custom programs or enhancements that reference the temperature dimension, review the code to ensure it is correctly implemented.
Consult Documentation:
- Review SAP documentation or notes related to unit of measure configuration for any additional guidance.
Contact SAP Support:
- If you are unable to resolve the issue, consider reaching out to SAP support for assistance.
Related Information:
By following these steps, you should be able to resolve the O3048 error and ensure that the temperature dimension is properly configured in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
O3047
Dimension "dimensionless" is missing in Table T006D
What causes this issue? There is no "dimensionless" dimension defined in Table T006D. Quantity Conversion Interface (QCI) processing is ter...
O3046
Quantity overflow; & is larger than 9,999,999,999.999
What causes this issue? A value has been calculated or manually entered that is too large to store within the system. A quantity cannot be larger tha...
O3049
Material & not maintained in the material master
What causes this issue? The material does not exist in the material master.How to fix this error? Check your material number and correct or maintain...
O3050
Plant & not maintained in the plant master
What causes this issue? The plant you have entered does not exist.How to fix this error? Enter a valid plant or maintain the plant data.Error messag...
Click on this link to search all SAP messages.