How To Fix NRSCNV356 - InfoObjects using &1 as compounded InfoObject already exist in &2


NRSCNV356 - Overview

  • Message type: E = Error

  • Message class: NRSCNV - Message class

  • Message number: 356

  • Message text: InfoObjects using &1 as compounded InfoObject already exist in &2

  • Show details Hide details
  • What causes this issue?

    You are trying to add characteristic &V1& to InfoProvider &V2& using a
    constant value as filling method. This is not possible, as other
    InfoObjects like &V3& that are also contained in InfoProvider &V2& are
    using characteristic &V1& as a compounded InfoObject. Adding &V1& might
    result in incorrect value pairs.

    System Response

    The check returned an error. The Remodeling Rule cannot be activated or
    scheduled.

    How to fix this error?

    Remove all InfoObjects that use &V1& as a compounded InfoObject from
    InfoProvider &V2&. Then add characteristic &V1& and then add all the
    InfoObjects that have been removed.

    Procedure for System Administrators

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message NRSCNV356 - InfoObjects using &1 as compounded InfoObject already exist in &2 ?
    The SAP error message NRSCNV356 indicates that there is an issue with InfoObjects in the context of data modeling or data warehousing, specifically when dealing with compounded InfoObjects. This error typically arises when you are trying to create or modify an InfoObject that is already defined as a compounded InfoObject in the system.
    
    Cause: The error message NRSCNV356 occurs due to the following reasons: Duplicate Definition: You are attempting to create a new InfoObject that is compounded with an existing InfoObject, but the existing InfoObject is already defined as a compounded InfoObject in the target InfoObject catalog. Inconsistent InfoObject Configuration: There may be inconsistencies in the configuration of InfoObjects, such as trying to redefine or modify an InfoObject that is already in use.
    Solution: To resolve the NRSCNV356 error, you can take the following steps: Check Existing InfoObjects: Go to the InfoObject maintenance transaction (e.g., RSA1 or RSD1) and check the existing InfoObjects in the target InfoObject

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant