Do you have any question about this error?
Message type: E = Error
Message class: LTR2_RN_CHECK - LTR2 RN: Renumbering project checking message class
Message number: 041
Message text: Object not compared yet
The comparison result of the number range object is missing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Reprocess the number range object.
Error message extract from SAP system. Copyright SAP SE.
LTR2_RN_CHECK041
- Object not compared yet ?The SAP error message LTR2_RN_CHECK041: Object not compared yet typically occurs in the context of SAP Landscape Transformation (SLT) or when working with data replication and transformation processes. This error indicates that a certain object (like a table or a data structure) has not been compared or synchronized between the source and target systems.
Cause:
- Initial Setup: The object in question has not been included in the initial comparison process. This can happen if the object was added after the initial configuration was set up.
- Replication Configuration: The replication configuration may not have been properly set up to include the object.
- Changes in Source System: If there have been changes in the source system (like new tables or changes to existing tables), these changes may not have been reflected in the target system.
- Technical Issues: There may be technical issues or inconsistencies in the SLT configuration or the underlying database.
Solution:
Perform Comparison:
- Go to the SLT configuration and perform a comparison for the object that is causing the error. This can usually be done through transaction codes like
LTRC
(for SLT configuration) orLTMC
(for migration cockpit).- Ensure that the object is included in the comparison process.
Check Replication Settings:
- Verify that the object is correctly configured for replication. Check the settings in the SLT configuration to ensure that the object is marked for replication.
Reinitialize Replication:
- If the object was added after the initial setup, you may need to reinitialize the replication for that object. This can involve deleting the existing configuration for that object and setting it up again.
Check Logs:
- Review the SLT logs for any additional error messages or warnings that might provide more context about why the object has not been compared.
Consult Documentation:
- Refer to SAP documentation or notes related to SLT and the specific error message for any additional troubleshooting steps or updates.
Contact SAP Support:
- If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
LTRC
(for SLT configuration), LTMC
(for migration cockpit), and SLT_LOG
(for viewing logs).By following these steps, you should be able to resolve the error message LTR2_RN_CHECK041 and ensure that your objects are properly compared and synchronized between the source and target systems.
Get instant SAP help. Start your 7-day free trial now.
LTR2_RN_CHECK040
No corresponding interval in receiver to adjust level
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_RN_CHECK039
Project adjustment mode '&1' is not valid
What causes this issue? Given adjustment mode is not valid.System Response The system issues an error message and will not allow you to continue wit...
LTR2_RN_CHECK042
Interval not analyzed yet
What causes this issue? The number range object may not exist in the remote systems or has been added after renumbering project execution.System Resp...
LTR2_RN_CHECK043
Interval not compared yet
What causes this issue? The comparison result of the number range interval is missing.System Response The system issues an error message and will no...
Click on this link to search all SAP messages.