Do you have any question about this error?
Message type: E = Error
Message class: LTR2_ES_CHECK - LTR2 Checks on Embedded Specification
Message number: 211
Message text: '&1' is used in receiver system system '&2/&3'
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
LTR2_ES_CHECK211
- '&1' is used in receiver system system '&2/&3' ?The SAP error message LTR2_ES_CHECK211 typically occurs in the context of SAP Landscape Transformation (SLT) Replication Server. This error indicates that a certain object (like a table or a field) is being used in the receiver system, which is causing a conflict or issue during the data replication process.
Cause:
The error message
LTR2_ES_CHECK211 '&1' is used in receiver system system '&2/&3'
suggests that the object identified by&1
is already in use in the target system (receiver system) identified by&2
and&3
. This can happen due to several reasons:
- Object Already Exists: The object you are trying to replicate already exists in the target system, and there may be a conflict in terms of structure or data.
- Data Type Mismatch: There may be a mismatch in the data types or definitions of the object between the source and target systems.
- Replication Configuration Issues: There may be issues with the configuration of the SLT replication settings.
Solution:
To resolve this error, you can take the following steps:
Check Object Existence: Verify if the object (table/field) identified by
&1
already exists in the target system (&2/&3
). If it does, check its structure and data types to ensure they match the source system.Adjust Replication Settings: If the object exists and is not intended to be replicated, you may need to adjust the SLT configuration to exclude this object from replication.
Modify Object in Target System: If the object in the target system needs to be updated or modified to match the source system, you may need to make the necessary changes in the target system.
Reconfigure SLT: If there are configuration issues, you may need to reconfigure the SLT settings for the replication process.
Consult Documentation: Refer to the SAP documentation for SLT for more detailed troubleshooting steps and best practices.
Check Logs: Review the SLT logs for more detailed error messages that can provide additional context on the issue.
Contact SAP Support: If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
LTR2_ES_CHECK210
'&1' is not used in sender system '&2/&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES_CHECK209
'&1' is used in sender system '&2/&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES_CHECK212
'&1' is not used in receiver system '&2/&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES_CHECK213
Setting '&1' must not be set on data models belonging to a sub-BO
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.