Do you have any question about this error?
Message type: E = Error
Message class: LTR2_ES -
Message number: 017
Message text: Embedded specification will be created in namespace "&1"
The entered namespace "&V2&" differs from system namespace "&V1&".
The namespace will be adapted to system namespace "&V1&".
Embedded specifications are always created in the system namespace. This
system behavior cannot be influenced by the user.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
LTR2_ES017
- Embedded specification will be created in namespace "&1" ?The SAP error message LTR2_ES017, which states "Embedded specification will be created in namespace '&1'", typically occurs in the context of SAP Landscape Transformation (SLT) or when working with Data Services. This message indicates that an embedded specification is being created in a specific namespace, which may not be what the user intended.
Cause:
- Namespace Conflict: The error often arises when there is a conflict or ambiguity in the namespace being used for the embedded specification. This can happen if the namespace is not properly defined or if there are multiple specifications that could potentially conflict with each other.
- Configuration Issues: There may be issues with the configuration of the SLT or Data Services environment, leading to the system attempting to create an embedded specification in an unintended namespace.
- Missing Authorizations: Sometimes, the user may not have the necessary authorizations to create or modify specifications in the intended namespace.
Solution:
- Check Namespace Configuration: Verify the configuration of the namespaces in your SLT or Data Services environment. Ensure that the namespace you are trying to use is correctly defined and does not conflict with existing namespaces.
- Review Embedded Specification Settings: Look into the settings for the embedded specification you are trying to create. Make sure that the parameters and options are set correctly to avoid unintended namespace creation.
- Authorization Check: Ensure that the user has the necessary authorizations to create or modify specifications in the desired namespace. You may need to consult with your SAP security team to verify and adjust user roles and permissions.
- Consult Documentation: Refer to the official SAP documentation for SLT or Data Services for guidance on handling namespaces and embedded specifications. This can provide insights into best practices and troubleshooting steps.
- Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP Support for further assistance. They can provide more specific guidance based on your system configuration and the context of the error.
Related Information:
By following these steps, you should be able to address the error message LTR2_ES017 and ensure that embedded specifications are created in the correct namespace.
Get instant SAP help. Start your 7-day free trial now.
LTR2_ES016
Storing PE data failed: &1
What causes this issue? Saving the embedded specification has been aborted because there occurred a serious error while storing posting engine data: ...
LTR2_ES015
Accessing ES failed: &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES018
New embedded specification named as &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LTR2_ES019
Source embedded specification &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.