Message type: E = Error
Message class: LT - LE-WM: View or Table Maintenance Error Messages
Message number: 175
Message text: Changing capacity check method can cause inconsistencies in the database
When the capacity check method was changed, the system found
<GL:quant>quants</> in <DS:GLOS.storage_type>storage type</> '&V2&' in
<GL:warehouse_number>warehouse number</> '&V1&'. Changing the check
method is only appropriate if the capacity data of the warehouse stock
has been corrected in the respective storage type.
If you want to change the capacity check in a storage type with
warehouse stock, you must recalculate the weight data after the field
change.
To do this, use the program <DS:RE.RLS10200>RLS10200</>.
Start the program via the menu <LS>"System -> Services -> Reporting"
</>.
Error message extract from SAP system. Copyright SAP SE.
LT175
- Changing capacity check method can cause inconsistencies in the database ?The SAP error message LT175 indicates that there is a potential inconsistency in the database when changing the capacity check method in the context of warehouse management. This error typically arises when the system detects that changing the capacity check method could lead to discrepancies in how inventory and capacity are managed within the warehouse.
Cause: Inconsistent Data: The primary cause of this error is that the existing data in the system may not align with the new capacity check method being implemented. For example, if there are existing stock levels, open transfer orders, or other inventory-related transactions that were processed under the old capacity check method, changing it could lead to inconsistencies. Active Transactions: If there are ongoing transactions or processes that rely on the current capacity check method, changing it could disrupt these processes and lead to data integrity issues.
Configuration Issues: The configuration settings for the warehouse management module may not
Get instant SAP help. Sign up for our Free Essentials Plan.
LT174
Capacity check "1" requires adaptation of storage bin data
What causes this issue? When the capacity check method was changed, the system found that <GL:storage_bin>storage bins</> in storage type...
LT173
Changes can cause data inconsistencies
What causes this issue? When this table was changed, the system found application data that references these table entries. Two examples: If the unit...
LT176
Only one standard stor.loc. per plant allowed in the same whse number
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LT177
Test storage type & is not defined
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.