Message type: E = Error
Message class: LM_SEMAPHORE - Messages for LM Sempahore Handling
Message number: 011
Message text: The semaphore for system &1, client &2, process type &3 cannot be deleted
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
LM_SEMAPHORE011
- The semaphore for system &1, client &2, process type &3 cannot be deleted ?The SAP error message LM_SEMAPHORE011 indicates that the system is unable to delete a semaphore for a specific system, client, and process type. Semaphores are used in SAP to manage access to shared resources and ensure that processes do not interfere with each other. Cause The error can occur due to several reasons: Process Still Running: The semaphore is still in use by a running process. If a process that is using the semaphore has not terminated properly, the semaphore cannot be deleted. Improper Shutdown: If the SAP system was not shut down properly, semaphores may not be released correctly. File System Issues: There may be issues with the file system where the semaphore files are stored, such as permission issues or corruption.
Configuration Issues: Incorrect configuration settings in the SAP system can lead to semaphore management problems. Solution To resolve the error, you can take the following steps: Check Running Processes: Use transaction SM50 or SM66 to check if
Get instant SAP help. Sign up for our Free Essentials Plan.
LM_SEMAPHORE010
The semaphore for system &1, client &2, process type &3 cannot be saved
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LM_SEMAPHORE009
Semaphore for system &1, client &2, process type &3 not created
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LM_SEMAPHORE012
The semaphore for system &1, client &2, process type &3 cannot be updated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
LM_SEMAPHORE013
&1, &2, proc. type &3, allowed proc. &4: error for removing allowed proc.
What causes this issue? The procedure tried to remove the process '&V4&' from the list of allowed processes of the LM Semaphore wit...
Click on this link to search all SAP messages.