Message type: E = Error
Message class: LE_SHP_BF_EAN128 - Messages for development class LE_SHP_BF_EAN128
Message number: 024
Message text: DB table &1 could not be blocked (access: &2, &3, &4)
The database table &MSGV1& could not be blocked. Access was attempted
using the key values "&MSGV2&", "
&MSGV3&", "&MSGV4&".
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
This is a temporary error. If it still occurs after several repeated
attempts, contact your administrator.
Error message extract from SAP system. Copyright SAP SE.
LE_SHP_BF_EAN128024
- DB table &1 could not be blocked (access: &2, &3, &4) ?The SAP error message LE_SHP_BF_EAN128024 indicates that there is an issue with blocking a database table during a transaction. This error typically occurs in the context of logistics and shipping processes, particularly when dealing with EAN-128 barcodes or similar logistics-related functionalities.
Cause: The error message "DB table &1 could not be blocked (access: &2, &3, &4)" suggests that the system is trying to lock a database table (indicated by &1) but is unable to do so due to existing access conflicts. The access types (&2, &3, &4) indicate the current locks or accesses that are preventing the operation. Common causes include: Concurrent Access: Another transaction or user is currently accessing the same database table, leading to a lock conflict. Long-running Transactions: A transaction that takes a long time to complete may hold locks longer than expected, causing other transactions to fail. Deadlocks: Situations where two or more transactions are waiting for each other to release
Get instant SAP help. Sign up for our Free Essentials Plan.
LE_SHP_BF_EAN128023
Parameter 'plant' must also be specified if 'stor.locat.' is specified
What causes this issue? To generate an SSCC, the plant must also be specified to determine the basis number of the ILN if the storage location was sp...
LE_SHP_BF_EAN128022
ILN basis no. for plant &1, stor.locat. &2 or whse number &3 not found
What causes this issue? The system could not find any parameters to generate an SSCC.System Response The system searched for these parameters in the...
LE_SHP_BF_EAN128025
DB table &1 could not be changed (&2, &3, &4)
What causes this issue? The database table &MSGV1& could not be changed. Access was attempted with the key values "&MSGV2&"...
LE_SHP_BF_EAN128026
Internal table &1 could not be changed (&2, &3, &4)
What causes this issue? The internal table "&MSGV1&" could not be changed. Access was attempted with the key values "&MSGV...