Do you have any question about this error?
Message type: E = Error
Message class: KJCCSJ3_BI01 - Japanese Estimation Procedure
Message number: 012
Message text: INTERNAL ERROR: Determination of start date not possible
The meter reading dates for meter reading documents &V1& and &V2&
generate a time interval according to the conventions for the valid
<DS:DE.BP>billing period</>.
The start date of the interval should be &V3&. If this is not the case,
then the corresponding meter reading from the previous time slice has
been used to determine the end date of the previous time slice. This end
date + 1 day is &V4&.
However, this is inconsistent, as &V4& is later than &V3&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE ISU_SAP OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
KJCCSJ3_BI01012
- INTERNAL ERROR: Determination of start date not possible ?The SAP error message KJCCSJ3_BI01012 INTERNAL ERROR: Determination of start date not possible typically occurs in the context of SAP Business Intelligence (BI) or SAP Controlling (CO) when the system is unable to determine a valid start date for a particular process or transaction. This can happen for various reasons, including configuration issues, missing data, or inconsistencies in the master data.
Possible Causes:
- Missing or Incorrect Master Data: The relevant master data (e.g., cost centers, profit centers, or other organizational units) may be missing or incorrectly configured.
- Data Inconsistencies: There may be inconsistencies in the data that prevent the system from determining a valid start date.
- Configuration Issues: The configuration settings for the relevant module (e.g., controlling, planning) may not be set up correctly.
- Authorization Issues: Lack of proper authorizations may prevent the system from accessing the necessary data.
- System Bugs: There may be a bug in the SAP system that is causing this internal error.
Solutions:
- Check Master Data: Verify that all relevant master data is complete and correctly configured. Ensure that all necessary records exist and are active.
- Review Configuration Settings: Check the configuration settings in the relevant module (e.g., CO configuration) to ensure they are set up correctly.
- Data Consistency Check: Run data consistency checks to identify and resolve any inconsistencies in the data.
- Authorization Check: Ensure that the user has the necessary authorizations to access the data required for the process.
- SAP Notes and Support: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates available that resolve the issue.
- Debugging: If you have access to technical resources, consider debugging the process to identify the exact point of failure and gather more information about the error.
- Contact SAP Support: If the issue persists and you cannot find a resolution, consider reaching out to SAP Support for assistance.
Related Information:
SE80
(Object Navigator) for debugging or SE37
(Function Module) for checking function modules related to the error.By following these steps, you should be able to identify the cause of the error and implement a solution.
Get instant SAP help. Start your 7-day free trial now.
KJCCSJ3_BI01011
No demand or change in demand -> Number of month weighting not possible
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
KJCCSJ3_BI01010
Installation &1: Reestimtion executed successfully
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
KJCCSJ3_BI01013
INTERNAL ERROR: Determination of end date not possible
What causes this issue? The meter reading date from meter reading document &V2& is used for installation &V1& to determine the <ZH...
KJCCSJ3_BI01014
INTERNAL ERROR: No relevant meter reading reason for extrapolation
What causes this issue? <ZH>INTERNAL ERROR:</> The system could not determine a dominant meter reading reason for the extrapolation for e...