Do you have any question about this error?
Message type: E = Error
Message class: /IWFND/COS_SUTIL -
Message number: 210
Message text: Executed &2 of &3 testcases / NOT OK: &4
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/IWFND/COS_SUTIL210
- Executed &2 of &3 testcases / NOT OK: &4 ?The SAP error message
/IWFND/COS_SUTIL210 Executed &2 of &3 testcases / NOT OK: &4
typically relates to issues encountered during the execution of test cases in the SAP Gateway framework, particularly when testing OData services. This error indicates that some test cases did not pass successfully.Cause:
- Service Configuration Issues: The OData service may not be properly configured or activated in the SAP Gateway.
- Authorization Problems: The user executing the test may not have the necessary authorizations to access the OData service or its underlying data.
- Data Issues: There may be issues with the data being accessed or manipulated by the OData service, such as missing or incorrect data.
- Service Implementation Errors: There could be bugs or issues in the implementation of the OData service itself, such as incorrect logic or missing methods.
- Network or Connectivity Issues: Problems with network connectivity or service availability can also lead to test failures.
Solution:
- Check Service Activation: Ensure that the OData service is activated in the SAP Gateway. You can do this using transaction code
/IWFND/MAINT_SERVICE
.- Review Authorizations: Verify that the user has the necessary authorizations to execute the OData service. You can check this in transaction code
SU53
after the error occurs.- Examine Test Case Details: Look at the specific test cases that failed (indicated by
&4
in the error message) to understand what went wrong. This may involve checking logs or debugging the service.- Data Validation: Ensure that the data being accessed by the OData service is valid and exists in the system. You may need to check the underlying database tables.
- Debugging: If the issue seems to be in the service implementation, use transaction
SE80
orSE24
to debug the service and identify any logical errors.- Check Logs: Review the application logs (transaction
SLG1
) for any additional error messages or warnings that could provide more context on the failure.- Network Checks: If applicable, ensure that there are no network issues affecting the connectivity to the SAP Gateway.
Related Information:
Transaction Codes:
/IWFND/MAINT_SERVICE
: Manage OData services.SE80
: Object Navigator for debugging.SE24
: Class Builder for checking class implementations.SLG1
: Application log for error messages.SU53
: Authorization check after an error occurs.SAP Notes: Check for any relevant SAP Notes that may address known issues with the specific version of SAP you are using.
Documentation: Refer to the SAP Gateway documentation for more details on OData service testing and troubleshooting.
By following these steps, you should be able to identify the root cause of the error and implement a solution.
Get instant SAP help. Start your 7-day free trial now.
/IWFND/COS_SUTIL209
Internal bgRFC error
What causes this issue? Internal bgRFC errorSystem Response The system issues an error message and will not allow you to continue with this transact...
/IWFND/COS_SUTIL208
Wait for Update Task
What causes this issue? When bgRFC and also Update Task are used in one Logical Unit of Work, the bgRFC unit will be processed automatically after th...
/IWFND/MED000
Service name and prefix too long
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWFND/MED001
The given model type key '&1' is not a valid meta model type
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.