Do you have any question about this error?
Message type: E = Error
Message class: /IWFND/COD -
Message number: 311
Message text: System has no system type ("SAP" or "CUSTOMER")
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/IWFND/COD311
- System has no system type ("SAP" or "CUSTOMER") ?The SAP error message
/IWFND/COD311 System has no system type ("SAP" or "CUSTOMER")
typically occurs in the context of SAP Gateway or OData services. This error indicates that the system type has not been defined correctly in the system settings, which is necessary for the proper functioning of the OData services.Cause:
- Missing System Type Configuration: The system type (either "SAP" or "CUSTOMER") has not been set in the system configuration.
- Incorrect System Settings: The system might be incorrectly configured, leading to the inability to identify the system type.
- Transport Issues: If the system was recently transported from another environment, the system type configuration might not have been included or might have been lost.
Solution:
To resolve this error, you need to define the system type in the SAP system settings. Here are the steps to do this:
Access the SAP Gateway Configuration:
- Go to transaction code
SPRO
.- Navigate to
SAP Reference IMG
>SAP NetWeaver
>Gateway
>OData Channel
>Configuration
>System Type
.Define the System Type:
- In the system type configuration, you should see options to set the system type.
- Set the system type to either "SAP" or "CUSTOMER" based on your requirements.
Save the Configuration:
- After making the changes, save the configuration.
Check the OData Services:
- After configuring the system type, check if the OData services are functioning correctly.
- You can use transaction code
/IWFND/MAINT_SERVICE
to manage and activate OData services.Restart the Gateway (if necessary):
- In some cases, you may need to restart the SAP Gateway service for the changes to take effect.
Related Information:
By ensuring that the system type is correctly defined, you should be able to resolve the /IWFND/COD311
error and restore the functionality of your OData services.
Get instant SAP help. Start your 7-day free trial now.
/IWFND/COD310
Process mode must be either co-deployed or routing based.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWFND/COD309
No changes to repository objects allowed.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWFND/COD312
&1 &2 &3 &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWFND/COD313
Development class of service group '&1' not found.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.