How To Fix /IWBEP/SBUIP028 - Generation of runtime objects for project '&1' not possible


SAP Error Message - Details

  • Message type: E = Error

  • Message class: /IWBEP/SBUIP -

  • Message number: 028

  • Message text: Generation of runtime objects for project '&1' not possible

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message /IWBEP/SBUIP028 - Generation of runtime objects for project '&1' not possible ?

    The SAP error message /IWBEP/SBUIP028 Generation of runtime objects for project '&1' not possible typically occurs in the context of SAP Gateway and OData service development. This error indicates that there was a failure in generating the runtime objects for a specific project, which can be due to various reasons.

    Causes:

    1. Missing or Incomplete Annotations: The project may have missing or incomplete annotations that are required for the generation of runtime objects.
    2. Syntax Errors: There could be syntax errors in the code or configuration files associated with the project.
    3. Transport Issues: If the project is being transported from one system to another, there may be issues with the transport request.
    4. Authorization Issues: The user may not have the necessary authorizations to generate runtime objects.
    5. Inconsistent Data: There may be inconsistencies in the underlying data model or database that prevent the generation process.
    6. System Configuration: There may be issues with the system configuration or settings that affect the generation process.

    Solutions:

    1. Check Annotations: Review the annotations in your project to ensure they are complete and correctly defined.
    2. Review Code for Errors: Check for any syntax errors or inconsistencies in your code. Use the ABAP editor to identify and correct any issues.
    3. Transport Request: If the project is being transported, ensure that the transport request is complete and correctly configured.
    4. Authorization Check: Verify that the user has the necessary authorizations to perform the generation of runtime objects.
    5. Data Consistency: Check the underlying data model for any inconsistencies or issues that may be causing the problem.
    6. System Logs: Review the system logs (transaction SLG1) for any additional error messages or information that may provide more context about the issue.
    7. Rebuild the Project: Sometimes, rebuilding the project or regenerating the service can resolve the issue. You can do this by using transaction /IWFND/MAINT_SERVICE to manage your OData services.
    8. Check SAP Notes: Look for any relevant SAP Notes that may address this specific error or provide additional guidance.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as /IWFND/MAINT_SERVICE for managing OData services and /IWBEP/REG_SERVICE for registering services.
    • SAP Gateway: Understanding the SAP Gateway framework and its components can help in troubleshooting issues related to OData services.
    • Documentation: Refer to the official SAP documentation for OData service development and troubleshooting for more detailed guidance.

    If the issue persists after trying the above solutions, consider reaching out to SAP support or consulting with a technical expert who specializes in SAP Gateway and OData services.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author