Do you have any question about this error?
Message type: E = Error
Message class: /IWBEP/CM_V4_MED -
Message number: 101
Message text: Complex type '&1' not found for property '&2' in complex type '&3'
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/IWBEP/CM_V4_MED101
- Complex type '&1' not found for property '&2' in complex type '&3' ?The SAP error message
/IWBEP/CM_V4_MED101
indicates that there is a problem with the OData service definition, specifically related to complex types. This error typically occurs when the OData service is trying to access a complex type that is not defined or is not recognized in the context of the service.Cause:
- Missing Complex Type Definition: The complex type
&1
that is being referenced in the property&2
of the complex type&3
is not defined in the OData service metadata.- Incorrect Mapping: There may be an issue with the mapping of the complex type in the service implementation or the data model.
- Service Activation Issues: The OData service may not be properly activated or there may be inconsistencies in the service definition.
- Versioning Issues: If there are multiple versions of the service, the complex type may exist in one version but not in another.
Solution:
- Check Metadata: Verify the metadata of the OData service to ensure that the complex type
&1
is defined correctly. You can access the metadata by appending$metadata
to the service URL.- Define Missing Complex Type: If the complex type is indeed missing, you will need to define it in the service's data model. This can be done in the ABAP backend using the appropriate transaction (e.g., SEGW for Service Builder).
- Review Service Implementation: Check the implementation of the OData service to ensure that the complex types are correctly referenced and mapped.
- Re-activate the Service: If changes have been made, re-activate the OData service to ensure that all definitions are up to date.
- Check for Version Conflicts: If you are working with multiple versions of the service, ensure that you are using the correct version that includes the required complex type.
Related Information:
SEGW
to access the Service Builder for OData services.IWFND/ERROR_LOG
to check for additional error logs related to the OData service.By following these steps, you should be able to identify and resolve the issue related to the error message /IWBEP/CM_V4_MED101
.
Get instant SAP help. Start your 7-day free trial now.
/IWBEP/CM_V4_MED100
Type definition '&1' not found for property '&2' in entity type '&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWBEP/CM_V4_MED099
Type definition '&1' not found for property '&2' in complex type '&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWBEP/CM_V4_MED102
Complex type '&1' not found for property '&2' in entity type '&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWBEP/CM_V4_MED103
Target entity type '&1' not found for nav-prop '&2' in complex type '&3'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.