Message type: E = Error
Message class: /IWBEP/CM_MGW_RT -
Message number: 092
Message text: Method '&1' not implemented in model provider class
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/IWBEP/CM_MGW_RT092
- Method '&1' not implemented in model provider class ?The SAP error message
/IWBEP/CM_MGW_RT092 Method '&1' not implemented in model provider class
typically occurs in the context of SAP Gateway and OData services. This error indicates that a specific method (likeGET
,POST
,PUT
,DELETE
, etc.) is being called on an OData service, but the corresponding method has not been implemented in the model provider class.Cause:
- Missing Implementation: The method that is being called is not implemented in the model provider class. This can happen if the service was generated but the necessary methods were not implemented.
- Incorrect Service Configuration: The OData service might not be correctly configured to handle the requested operation.
- Model Provider Class Issues: There may be issues with the model provider class itself, such as it not being activated or not being correctly associated with the OData service.
- Service Versioning: If there are multiple versions of the service, the wrong version might be called that does not have the method implemented.
Solution:
Implement the Missing Method:
- Go to the model provider class (usually a class that implements the interface
IF_MGW_APPL_SRV
).- Implement the required method (e.g.,
GET_ENTITY
,CREATE_ENTITY
, etc.) based on the operation that is being called.- Ensure that the method signature matches what is expected by the OData framework.
Check Service Configuration:
- Ensure that the OData service is correctly configured in the SAP Gateway Service Builder (transaction code
SEGW
).- Check the service registration in transaction
/IWFND/MAINT_SERVICE
to ensure it is active.Activate the Model Provider Class:
- If you have made changes to the model provider class, ensure that it is activated. You can do this in the ABAP Workbench (transaction
SE80
).Debugging:
- Use the debugger to trace the execution and see where the call is failing. This can provide insights into whether the correct method is being called and why it is not implemented.
Check for Versioning Issues:
- If you have multiple versions of the service, ensure that you are calling the correct version that has the method implemented.
Related Information:
If you continue to face issues after implementing the above solutions, consider checking SAP Notes or reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
/IWBEP/CM_MGW_RT091
Caching on hub not allowed by configuration (Softstate or Service Config)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWBEP/CM_MGW_RT090
Property conversion not allowed because model is set to "no conversions"
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWBEP/CM_MGW_RT093
Provided text type for the annotation simple value is not supported
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/IWBEP/CM_MGW_RT094
Provided text element symbol for the simple value may not be initial
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.