Do you have any question about this error?
Message type: E = Error
Message class: ITOB_FLEET - Messages for Development Class ITOB for Fleet Objects
Message number: 406
Message text: Measurement position & not set up as a primary counter in Customizing
You have specified a measurement position for the primary counter that
is not assigned to counter reading '1' = 'consumption-relevant distance
counter' or '2' = 'consumption-relevant time counter' in Customizing.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check your entry.
Error message extract from SAP system. Copyright SAP SE.
ITOB_FLEET406
- Measurement position & not set up as a primary counter in Customizing ?The SAP error message ITOB_FLEET406 indicates that a measurement position is not set up as a primary counter in the system's configuration. This error typically occurs in the context of fleet management or asset management when trying to record or process measurements for a vehicle or asset.
Cause:
The error arises when the system expects a measurement position (like mileage, hours, etc.) to be designated as a primary counter, but it is not configured as such in the system. This can happen due to:
- Configuration Issues: The measurement position has not been properly defined in the Customizing settings.
- Missing Settings: The primary counter settings for the measurement position are missing or incorrectly set.
- Data Entry Errors: Incorrect data entry or selection of measurement positions during transactions.
Solution:
To resolve the ITOB_FLEET406 error, follow these steps:
Check Customizing Settings:
- Go to the SAP Customizing Implementation Guide (IMG).
- Navigate to Fleet Management > Measurement Points > Define Measurement Positions.
- Ensure that the measurement position in question is set up correctly and marked as a primary counter.
Define Primary Counter:
- In the same section, check if the measurement position is defined as a primary counter. If not, you will need to edit the settings to designate it as such.
Review Measurement Position Assignment:
- Ensure that the measurement position is correctly assigned to the relevant vehicle or asset in the system.
Test the Configuration:
- After making the necessary changes, test the configuration by trying to record a measurement again to see if the error persists.
Consult Documentation:
- If you are unsure about the settings, refer to SAP documentation or help resources for detailed guidance on configuring measurement positions and primary counters.
Related Information:
SPRO
for accessing the Customizing settings or IW31/IW32
for work order management.If the issue persists after following these steps, consider reaching out to your SAP support team or consulting with an SAP expert for further assistance.
Get instant SAP help. Start your 7-day free trial now.
ITOB_FLEET405
Measurement pos. & has not been set up as a fuel counter in Customizing
What causes this issue? You have specified a measurement position for the fuel counter that is not assigned to counter reading '3' = '...
ITOB_FLEET404
Measurement position & not allowed in Fleet Management
What causes this issue? You have specified a measurement position for which there is no Customizing setting for Fleet Management.System Response The...
ITOB_FLEET407
The dimension of unit of measurement &1 is not suitable for unit group &2
What causes this issue? The units of measurement of a unit group belong either to the same dimension as the relevant SI unit or to the inverse dimens...
ITOB_FLEET408
No valid dimension was found for unit of measurement &
What causes this issue? No valid dimension was found for the unit of measurement you have selected. This unit of measurement is therefore unsuitable ...
Click on this link to search all SAP messages.