Do you have any question about this error?
Message type: E = Error
Message class: ISUPFC - Messages for Price Simulation
Message number: 018
Message text: Unit of measurement &1 for annual consumption not suitable for device &3
You have entered an annual consumption with unit of measurement &v1& for
the simulation of device &v3&, register &v4&. However, the register is
billed with <DS:DE.E_MASS>unit of measurement</> &v2&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
ISUPFC018
- Unit of measurement &1 for annual consumption not suitable for device &3 ?The SAP error message ISUPFC018 indicates that there is an issue with the unit of measurement (UoM) for the annual consumption of a device. This error typically arises in the context of SAP IS-U (Industry Solution for Utilities) when dealing with device management and consumption data.
Cause:
The error message ISUPFC018 is triggered when the unit of measurement specified for the annual consumption of a device does not match the expected or allowed unit of measurement for that particular device type. This can occur due to several reasons, including:
- Incorrect Configuration: The device type may not be configured to accept the specified unit of measurement for annual consumption.
- Data Entry Error: There may have been a mistake in entering the unit of measurement in the device master data or in the consumption data.
- Incompatibility: The unit of measurement may not be compatible with the measurement type or the device category.
Solution:
To resolve the ISUPFC018 error, you can take the following steps:
Check Device Configuration:
- Go to the device master data and verify the configuration settings for the device type. Ensure that the unit of measurement for annual consumption is correctly defined and compatible with the device.
Review Unit of Measurement:
- Check the unit of measurement that is being used for annual consumption. Ensure that it is valid and appropriate for the device type. You can do this by navigating to the relevant configuration settings in SAP.
Adjust Data Entry:
- If the error is due to incorrect data entry, correct the unit of measurement in the relevant transaction or data entry screen.
Consult Documentation:
- Refer to SAP documentation or configuration guides for the specific device type to understand the expected units of measurement and any restrictions that may apply.
Testing:
- After making the necessary adjustments, test the changes by attempting to save or process the data again to ensure that the error no longer occurs.
Seek Help from SAP Support:
- If the issue persists after checking the configuration and data entry, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration.
Related Information:
EL31
(Device Management) or EL30
(Device Master Data) to access and modify device-related information.By following these steps, you should be able to identify and resolve the cause of the ISUPFC018 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
ISUPFC017
Annual consumptions number does not match number of registers
What causes this issue? The number of annual consumption values is &v1&. The number of registers in the sample installation &v2& does...
ISUPFC016
No register found for register code &1
What causes this issue? During simulation of sample template &v2&, you tried to assign an annual consumption to a register with <DS:DE.KEN...
ISUPFC019
CRM product &1 with master data template &2 successfully simulated
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ISUPFC020
Contract template &1 simulated from &2 to &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.