Message type: E = Error
Message class: ISSR_TP - Message Class for Statutory Reporting
Message number: 756
Message text: Field name & in dynamic SELECT is longer than 66 characters
The field name &V1& for the dynamic SELECT from table &V2& in function
module &V3& is longer than 66 characters.
The program terminates processing.
Check import parameters when you call function module &V3&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
ISSR_TP756
- Field name & in dynamic SELECT is longer than 66 characters ?The SAP error message ISSR_TP756 indicates that a field name used in a dynamic SELECT statement exceeds the maximum allowed length of 66 characters. This is a common issue when working with dynamic SQL in ABAP, particularly when constructing queries that involve long field names or concatenated strings.
Cause: The error occurs because: In ABAP, the maximum length for field names in dynamic SQL statements is restricted to 66 characters. If you are trying to use a field name that is longer than this limit, the system will throw this error.
Solution: To resolve this issue, you can take the following steps: Shorten Field Names: If possible, use shorter field names in your dynamic SELECT statement. This may involve using aliases or renaming fields in your database view or table. Use Views: If you are working with database tables, consider creating a database view that includes only the necessary fields with shorter names. This way, you can reference
Get instant SAP help. Sign up for our Free Essentials Plan.
ISSR_TP755
Field &1 does not exist in table &2
What causes this issue? An error occurred when function module &V3& was called: The field &V1& does not exist in table &V2&.S...
ISSR_TP754
SR mass transf. posting: CC/SR var. &; ass.no./sec. acc./ass. ty./user &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ISSR_TP757
Dynamic condition table for SELECT could not be created
What causes this issue? While calling function module &V2&, the system could not create the condition table required for the dynamic SELECT f...
ISSR_TP758
Structure & is not a database table/database view
What causes this issue? The structure name &V1& transferred to function module &V2& using interface parameter <AB>IV_TABNAME<...
Click on this link to search all SAP messages.