How To Fix /ISDFPS/LM_CUS132 - Measuring point for usage rate could be found for equipment &1


SAP Error Message - Details

  • Message type: E = Error

  • Message class: /ISDFPS/LM_CUS -

  • Message number: 132

  • Message text: Measuring point for usage rate could be found for equipment &1

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message /ISDFPS/LM_CUS132 - Measuring point for usage rate could be found for equipment &1 ?

    The SAP error message /ISDFPS/LM_CUS132 Measuring point for usage rate could not be found for equipment &1 typically occurs in the context of SAP's Industry Solution for Defense and Security (ISDFPS) or similar modules where equipment and measuring points are managed.

    Cause:

    This error indicates that the system is unable to find a measuring point associated with the specified equipment. The measuring point is essential for tracking usage rates, consumption, or other metrics related to the equipment. The possible causes for this error include:

    1. Missing Measuring Point: The measuring point has not been created or is not assigned to the equipment in question.
    2. Incorrect Equipment Number: The equipment number provided may be incorrect or does not exist in the system.
    3. Configuration Issues: There may be configuration issues in the system that prevent the measuring point from being recognized.
    4. Data Inconsistencies: There could be inconsistencies in the master data related to the equipment or measuring points.

    Solution:

    To resolve this error, you can take the following steps:

    1. Check Equipment Master Data:

      • Verify that the equipment number (&1) is correct and exists in the system.
      • Use transaction code IE03 to display the equipment master data and check for any discrepancies.
    2. Create or Assign Measuring Point:

      • If the measuring point does not exist, you may need to create it. Use transaction code IK01 to create a new measuring point and ensure it is linked to the correct equipment.
      • If the measuring point exists but is not assigned to the equipment, you can assign it using transaction code IK02.
    3. Review Configuration:

      • Check the configuration settings related to measuring points and usage rates in the relevant customizing settings (transaction code SPRO).
      • Ensure that the necessary settings for measuring points and their association with equipment are correctly configured.
    4. Data Consistency Check:

      • Run any relevant data consistency checks or reports to identify and rectify any inconsistencies in the master data.
    5. Consult Documentation:

      • Review SAP documentation or notes related to the specific module you are working with for any additional guidance or known issues.
    6. Contact Support:

      • If the issue persists after checking the above points, consider reaching out to your SAP support team or consulting SAP Notes for further assistance.

    Related Information:

    • Transaction Codes:

      • IE03: Display Equipment
      • IK01: Create Measuring Point
      • IK02: Change Measuring Point
      • SPRO: Customizing Implementation Guide
    • SAP Notes: Check for any relevant SAP Notes that may address this specific error message or provide additional troubleshooting steps.

    By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael