Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 752
Message text: Incorrect measurement reading transfer &1
The measurement reading transfer for the measuring point &V1& contains
errors. Possible causes for this are as follows:
The measuring point from which the measurement reading transfer is to
take place does not exist.
The measurement reading transfer is to take place from several measuring
points. However, the measurement reading transfer must be unambiguous.
The measuring point category of the two measuring points for the
measurement reading transfer is not clearly defined. Values can only be
transferred from one counter to another counter, or from one non-counter
to another.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Contact your system administrator.
The BAdI <ZH>MP_TRANSFER_RELATION</> might have been implemented
incorrectly..
Error message extract from SAP system. Copyright SAP SE.
IR752
- Incorrect measurement reading transfer &1 ?The SAP error message IR752 "Incorrect measurement reading transfer &1" typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with measurement documents and the transfer of measurement readings.
Cause: The error message IR752 can be triggered by several factors, including: Incorrect Data Format: The measurement reading being transferred may not conform to the expected format or data type. This could include issues like incorrect decimal places, invalid characters, or out-of-range values. Missing or Incomplete Data: Required fields for the measurement reading may be missing or incomplete, leading to the inability to process the reading correctly.
Configuration Issues: There may be configuration settings in the SAP system that are not aligned with the data being transferred, such as incorrect settings for measurement points or devices. Business Logic Violations: The reading may violate business rules defined in the system, such as attempting to enter a reading that is lower than
Get instant SAP help. Sign up for our Free Essentials Plan.
IR751
API only supports measurement reading transfer within meas. point object
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR750
Incorrect interface use: & & & &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR753
No measuring point is specified for the measurement reading transfer
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR754
Interval documents can only be created for counters
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.