Do you have any question about this error?
Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 752
Message text: Incorrect measurement reading transfer &1
The measurement reading transfer for the measuring point &V1& contains
errors. Possible causes for this are as follows:
The measuring point from which the measurement reading transfer is to
take place does not exist.
The measurement reading transfer is to take place from several measuring
points. However, the measurement reading transfer must be unambiguous.
The measuring point category of the two measuring points for the
measurement reading transfer is not clearly defined. Values can only be
transferred from one counter to another counter, or from one non-counter
to another.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Contact your system administrator.
The BAdI <ZH>MP_TRANSFER_RELATION</> might have been implemented
incorrectly..
Error message extract from SAP system. Copyright SAP SE.
IR752
- Incorrect measurement reading transfer &1 ?The SAP error message IR752 "Incorrect measurement reading transfer &1" typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module, particularly when dealing with measurement documents and the transfer of measurement readings.
Cause:
The error message IR752 can be triggered by several factors, including:
Incorrect Data Format: The measurement reading being transferred may not conform to the expected format or data type. This could include issues like incorrect decimal places, invalid characters, or out-of-range values.
Missing or Incomplete Data: Required fields for the measurement reading may be missing or incomplete, leading to the inability to process the reading correctly.
Configuration Issues: There may be configuration settings in the SAP system that are not aligned with the data being transferred, such as incorrect settings for measurement points or devices.
Business Logic Violations: The reading may violate business rules defined in the system, such as attempting to enter a reading that is lower than a previous reading for the same period.
Authorization Issues: The user attempting to transfer the measurement reading may not have the necessary authorizations to perform this action.
Solution:
To resolve the IR752 error, consider the following steps:
Check Data Format: Ensure that the measurement reading being transferred adheres to the expected format. Validate the data for any incorrect characters or formats.
Complete Required Fields: Verify that all mandatory fields are filled out correctly. Check for any missing information that is required for the measurement reading.
Review Configuration: Examine the configuration settings related to measurement points and devices in the SAP system. Ensure that they are set up correctly and are compatible with the data being transferred.
Validate Business Rules: Check if the reading being entered complies with the business rules defined in the system. Ensure that it does not violate any constraints, such as being lower than previous readings.
Check Authorizations: Confirm that the user has the necessary permissions to perform the measurement reading transfer. If not, work with your SAP security team to obtain the required access.
Consult Documentation: Refer to SAP documentation or notes related to the IS-U module for any specific guidance on handling measurement reading errors.
Debugging: If the issue persists, consider using debugging tools in SAP to trace the process and identify where the error is occurring.
Related Information:
By following these steps, you should be able to identify the root cause of the IR752 error and implement an appropriate solution.
Get instant SAP help. Start your 7-day free trial now.
IR751
API only supports measurement reading transfer within meas. point object
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR750
Incorrect interface use: & & & &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR753
No measuring point is specified for the measurement reading transfer
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR754
Interval documents can only be created for counters
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...