Do you have any question about this error?
Message type: E = Error
Message class: IR - PM: IMRC - Measurement Readings and Counters
Message number: 519
Message text: Measurement transfer for ref. meas. points only inside the object hierary
You have assigned another measuring point, from which
<DS:GLOS.measurement values>measurement values</> or
<DS:GLOS.counter readings>counter readings</> should be received, to the
current <DS:GLOS.measurement values>measurement values</>.
The system determined the following during the check of the assigned
measuring point &V2&:
either the corresponding measuring point object does not belong to the
same hierarchy of measuring point objects as the measuring point object
of the current measuring point
or the corresponding measuring point object does belong to the same
hierarchy but is not in a direct line above it.
This assignment is not supported for reference measuring points.
Check your entry and correct the object hierarchy if necessary.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
IR519
- Measurement transfer for ref. meas. points only inside the object hierary ?The SAP error message IR519, which states "Measurement transfer for reference measurement points only inside the object hierarchy," typically occurs in the context of measurement documents or measurement points in SAP Plant Maintenance (PM) or similar modules. This error indicates that the system is trying to transfer measurement data for reference measurement points that are not properly linked within the object hierarchy.
Cause:
- Incorrect Hierarchy Structure: The measurement points may not be correctly structured within the object hierarchy. This can happen if the reference measurement points are not assigned to the correct parent object or if there are missing links in the hierarchy.
- Reference Measurement Points: The system is attempting to process measurement points that are designated as reference points, which are not intended for direct measurement transfers.
- Configuration Issues: There may be configuration issues in the measurement point settings or in the object hierarchy setup.
Solution:
- Check Object Hierarchy: Review the object hierarchy in the SAP system to ensure that all measurement points are correctly assigned to their respective parent objects. Make sure that the reference measurement points are properly linked.
- Review Measurement Points: Verify the settings of the measurement points involved. Ensure that they are not incorrectly marked as reference points if they are intended to be used for measurement transfers.
- Adjust Configuration: If necessary, adjust the configuration settings for measurement points and object hierarchies in the SAP system to ensure they align with the intended use.
- Use Correct Measurement Points: Ensure that you are using the correct measurement points for the transfer process. If you are trying to transfer measurements for reference points, consider using actual measurement points instead.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling measurement points and object hierarchies.
Related Information:
IK01
(Create Measurement Point), IK02
(Change Measurement Point), or IK03
(Display Measurement Point) to manage measurement points.If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a technical consultant who can provide more in-depth analysis and assistance.
Get instant SAP help. Start your 7-day free trial now.
IR518
Measurement transfers from meas.pt objects outside direct hierarchy line
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR517
Measurement transfers come from lower-level measuring point objects
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR520
Measurement transfer only allowed within same meas. point object types
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
IR526
User &1 is currently editing reference meas. point &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.