Message type: E = Error
Message class: IM - Maintenance notifications
Message number: 672
Message text: Screen areas '090'/'100' cannot be used together with '091'/'101'
You used the screen areas '090' and '091' together. This is not
possible as screen area '090' (customer subscreen - a
screen/notification type) only allows one customer-specific screen area
for each notification type.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you want to use several customer-specific subscreens in your
notification type, only use screen area '091' in Customizing for this
notification type. The respective screen to be used can be assigned
directly to the screen area '091'.
Error message extract from SAP system. Copyright SAP SE.
IM672
- Screen areas '090'/'100' cannot be used together with '091'/'101' ?The SAP error message IM672 indicates that there is a conflict in the screen areas being used in a particular transaction or program. Specifically, it states that the screen areas '090'/'100' cannot be used together with '091'/'101'. This typically occurs in the context of screen programming or when dealing with user interfaces in SAP.
Cause: The error arises when there is an attempt to use incompatible screen areas in a single screen or transaction. In SAP, screen areas are defined for different purposes, and certain areas are not designed to be used together. For example, areas '090' and '100' might be intended for one type of display or interaction, while '091' and '101' are meant for another. Mixing these areas can lead to conflicts in how the screen is rendered or how user input is processed.
Solution: To resolve this error, you can take the following steps: Check Screen Configuration: Review the screen configuration in
Get instant SAP help. Sign up for our Free Essentials Plan.
IM671
The selected segmentation of the tab index is not permitted
What causes this issue? You have selected a division for the current tab strip which is not permissible.System Response The system issues an error m...
IM670
Maintain a screen from the function group XQQM as &1
What causes this issue? You have chosen '091' as the screen area. You must assign a screen created using enhancement QQMA0001 in developmen...
IM673
Not possible to compare the notification and object data
What causes this issue? It is not possible to copy the reference object data into the notification, as the maintenance planning plant of the referenc...
IM700
*********** General QM Notification Processing **************_
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...