Do you have any question about this error?
Message type: E = Error
Message class: IFME_TREE_CHECK -
Message number: 094
Message text: Node &1 must use the same delimiter settings as node &2
You selected the <LB>Delimiter Always Used</> value as field separation
for a specific record and defined a field delimiter for that. However,
after this record, there is another one that has a different setting
either for the <LS>Field Separation</> or <LS>Field Delimiter </>fields.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you select the value <LB>Delimiter Always Used</> as field separation
for a record, you must ensure that all the records processed after that
record have the same delimiter settings.
Error message extract from SAP system. Copyright SAP SE.
IFME_TREE_CHECK094
- Node &1 must use the same delimiter settings as node &2 ?The SAP error message IFME_TREE_CHECK094 indicates that there is a mismatch in the delimiter settings between two nodes in a hierarchical structure, typically in the context of a master data or configuration tree. This error often arises when you are trying to create or modify a structure that involves multiple nodes, and the delimiter settings (such as the character used to separate values) for these nodes do not match.
Cause:
The primary cause of this error is that the nodes in question are expected to have consistent delimiter settings, but they currently do not. This can happen due to:
To resolve this error, you need to ensure that the delimiter settings for the nodes in question are consistent. Here are the steps you can take:
Identify the Nodes: Determine which nodes are causing the issue. The error message will specify the node numbers (e.g., &1 and &2).
Check Delimiter Settings:
Align Delimiter Settings:
Save Changes: After making the necessary adjustments, save your changes and try to execute the operation again that previously resulted in the error.
Test the Configuration: After resolving the issue, test the configuration to ensure that it works as expected without triggering the error again.
By following these steps, you should be able to resolve the IFME_TREE_CHECK094 error and ensure that your hierarchical structure is correctly configured.
Get instant SAP help. Start your 7-day free trial now.
IFME_TREE_CHECK093
If delimiters are always used, record &1 cannot contain more records
What causes this issue? You selected the <LB>Delimiter Always Used</> value as field separation either under <LS>Format Mapping Pro...
IFME_TREE_CHECK092
Select the Default value for Field Separation
What causes this issue? You selected the <LB>Delimiter Always Used </>value in the <LS>Default Field Separation </>field unde...
IFME_TREE_CHECK095
Record must have a record tag if it is after a record group
What causes this issue? You selected the <LB>Delimiter Always Used</> value as field separation either under <LS>Format Mapping Pro...
IFME_TREE_CHECK097
There is no append action for table &1&2&3 after field &4
What causes this issue? There is a field node in your format mapping, for which you have defined an output field. However, you have not defined an ap...
Click on this link to search all SAP messages.