Do you have any question about this error?
Message type: E = Error
Message class: ICL - FS-CM: Claims Management
Message number: 858
Message text: Structure &2 does not contain field &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
ICL858
- Structure &2 does not contain field &1 ?The SAP error message ICL858 indicates that a specific structure does not contain a field that is being referenced. This error typically occurs in the context of SAP's Insurance and Financial Services modules, particularly when dealing with data structures related to insurance claims or policies.
Cause:
The error is caused by one of the following reasons:
- Field Mismatch: The field being referenced in the code or configuration does not exist in the specified structure. This could be due to a typo, an outdated reference, or a change in the data model.
- Incorrect Structure: The structure being used may not be the correct one for the operation being performed. This can happen if the wrong structure is specified in the program or configuration.
- Versioning Issues: If there have been recent updates or changes to the SAP system, the structure may have been modified, and the code referencing it has not been updated accordingly.
Solution:
To resolve the ICL858 error, you can take the following steps:
Check the Structure Definition:
- Use transaction SE11 (Data Dictionary) to check the definition of the structure mentioned in the error message. Verify that the field being referenced actually exists in that structure.
Review the Code/Configuration:
- If you have access to the ABAP code or configuration where the error is occurring, review it to ensure that the correct structure and field names are being used. Look for any typos or incorrect references.
Update Code/Configuration:
- If you find that the field does not exist in the structure, you may need to update the code or configuration to reference the correct field or structure. If the field is supposed to exist but does not, you may need to consult with your SAP development team to determine if it should be added.
Check for Recent Changes:
- If the error started occurring after a recent update or change in the system, check the change logs or consult with your SAP Basis team to identify any modifications that may have affected the structure.
Consult Documentation:
- Review any relevant SAP documentation or release notes that may provide insights into changes in the data model or structures related to the error.
Testing:
- After making the necessary changes, perform thorough testing to ensure that the error is resolved and that the system behaves as expected.
Related Information:
By following these steps, you should be able to identify the cause of the ICL858 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
ICL857
Choose a valid line
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ICL856
Only one decimal place is permitted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
ICL859
Function module &1 does not have a suitable interface
What causes this issue? The interface must only have the following optional parameters: E_VALUE, reference category SYMSGV E_TYPE, reference category...
ICL860
Function module &1 does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.