Do you have any question about this error?
Message type: E = Error
Message class: /IBX/PE_FILE_SRV -
Message number: 034
Message text: Constructor of file service class &1 is PROTECTED
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/IBX/PE_FILE_SRV034
- Constructor of file service class &1 is PROTECTED ?The SAP error message
/IBX/PE_FILE_SRV034 Constructor of file service class &1 is PROTECTED
typically indicates that there is an issue with the instantiation of a class in the ABAP environment. Specifically, it suggests that the constructor method of the specified class is declared asPROTECTED
, which means that it cannot be instantiated directly outside of the class or its subclasses.Cause:
- Protected Constructor: The class you are trying to instantiate has a constructor that is marked as
PROTECTED
. This means that only the class itself or its subclasses can create instances of it.- Incorrect Usage: The code attempting to create an instance of this class is likely not within a subclass or is trying to instantiate it directly, which is not allowed.
Solution:
- Check Class Definition: Review the class definition of the specified class (replace
&1
with the actual class name in the error message). Look for the constructor method and confirm that it is indeed marked asPROTECTED
.- Use Subclassing: If you need to create an instance of this class, consider creating a subclass that inherits from it. You can then instantiate the subclass, which can call the protected constructor of the parent class.
- Factory Method: If the class provides a factory method (a static method that returns an instance of the class), use that method instead of trying to instantiate the class directly.
- Review Documentation: Check the SAP documentation or any related documentation for the class to understand how it is intended to be used.
Related Information:
PUBLIC
, PROTECTED
, and PRIVATE
. Understanding these visibility levels is crucial for proper class design and usage.By following these steps, you should be able to resolve the error and understand the underlying cause.
Get instant SAP help. Start your 7-day free trial now.
/IBX/PE_FILE_SRV033
Constructor of file service class &1 is PRIVATE
What causes this issue? The system cannot generate the object of file service class &V1& because the instance generation is PRIVATE. The clas...
/IBX/PE_FILE_SRV032
File service class &1 does not exist
What causes this issue? The system cannot generate the object of file service class &V1& for file access ID &V2&.System Response Pro...
/IBX/PE_FILE_SRV035
File service class &1 is not serializable
What causes this issue? The system cannot generate the object of file service class &V1&. The class is assigned to file access ID &V2&...
/IBX/PE_FILE_SRV036
Unable to generate file service class &1
What causes this issue? The system cannot generate the object of file service class &V1&. The class is assigned to file access ID &V2&...
Click on this link to search all SAP messages.