Do you have any question about this error?
Message type: E = Error
Message class: HRPIQ00ST_E - Student Maintenance (PMIQ_E)
Message number: 701
Message text: Infotype group &1 not defined
The infotype group &V1& is not defined.
The processing is terminated.
<DS:SIMG.CM_AS_XX_602>Define and Maintain Infotype Group</> in
customizing for Student Lifecycle Management.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
HRPIQ00ST_E701
- Infotype group &1 not defined ?The SAP error message HRPIQ00ST_E701 indicates that there is an issue with the infotype group specified in the system. Specifically, the error message states that the infotype group (&1) is not defined. This typically occurs in the context of SAP HR (Human Resources) or SAP Student Lifecycle Management (SLcM) when the system is trying to access or process data related to a specific infotype group that has not been configured or is missing.
Cause:
- Undefined Infotype Group: The specified infotype group does not exist in the system. This could be due to a configuration error or because the infotype group was never created.
- Incorrect Configuration: The infotype group may have been incorrectly configured or deleted.
- Transport Issues: If the system is part of a landscape where transports are used, the infotype group may not have been transported correctly from the development environment to the production environment.
- Custom Development: If there are custom developments or enhancements, they may reference an infotype group that is not defined.
Solution:
Check Infotype Group Configuration:
- Go to the transaction code SPRO (SAP Reference IMG).
- Navigate to the relevant section for HR or SLcM where infotype groups are defined.
- Verify if the infotype group in question is defined. If not, you may need to create it.
Create or Modify Infotype Group:
- If the infotype group is missing, you can create it using the appropriate configuration settings.
- If it exists but is incorrectly configured, make the necessary adjustments.
Check for Transport Issues:
- If the issue arose after a transport, check the transport logs to ensure that all necessary objects were transported correctly.
- If needed, re-transport the missing infotype group.
Review Custom Code:
- If there are custom programs or enhancements that reference the infotype group, review the code to ensure it is referencing the correct infotype group.
- Update the code if necessary to point to a valid infotype group.
Consult Documentation:
- Review SAP documentation or notes related to the specific infotype group and its usage to ensure compliance with best practices.
Contact SAP Support:
- If you are unable to resolve the issue, consider reaching out to SAP support for assistance, especially if this is a critical issue affecting business processes.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
HRPIQ00ST_E700
No infotype group maintained for infotype &1 and subtype &2
What causes this issue? No infotype group is assigned for the infotype &V1& and subtype &V2&.System Response The processing is termi...
HRPIQ00ST_E602
Business partner category &1 not allowed; please select again
What causes this issue? Business partner category &V1& is not allowed, please select againSystem Response The business partner you selected ...
HRPIQ00ST_E750
Notification &1 is not for student &2; check your input
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
HRPIQ00ST_E751
No notification number is assigned to line &; check your input
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.