Do you have any question about this error?
Message type: E = Error
Message class: GK - Messages for SAP Consolidation
Message number: 555
Message text: Bottum-up inheritance not allowed for &3
A C/I method was already inherited downwards from &V1& &V2&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
GK555
- Bottum-up inheritance not allowed for &3 ?The SAP error message GK555, which states "Bottom-up inheritance not allowed for &3," typically occurs in the context of SAP's Profitability Analysis (CO-PA) module. This error is related to the way characteristics are inherited in the data structure of CO-PA.
Cause:
The error arises when there is an attempt to perform bottom-up inheritance for a characteristic that does not support it. In CO-PA, characteristics can be defined to inherit values from higher levels (top-down) or lower levels (bottom-up). However, certain characteristics are not designed to allow bottom-up inheritance due to the nature of the data or the configuration settings.
Solution:
To resolve the GK555 error, you can take the following steps:
Check Characteristic Configuration: Review the configuration of the characteristic that is causing the error (indicated by &3 in the message). Ensure that it is set up correctly and that bottom-up inheritance is appropriate for this characteristic.
Adjust Inheritance Settings: If bottom-up inheritance is not allowed for the characteristic, consider changing the inheritance settings to top-down inheritance if that aligns with your business requirements.
Review Data Structure: Ensure that the data structure and hierarchy in CO-PA are correctly defined. Sometimes, the error can occur due to inconsistencies in the data model.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the characteristic in question and its inheritance rules.
Seek Support: If the issue persists, consider reaching out to your SAP support team or consulting with an SAP expert who can provide more tailored assistance based on your specific configuration and requirements.
Related Information:
By following these steps, you should be able to identify the root cause of the GK555 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
GK554
Top-down inheritance not allowed for &3
What causes this issue? A C/I method was already inherited upwards from &V1& &V2&.System Response The system issues an error message...
GK553
Method assignment for &1 &2 deleted.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GK556
The method &3 was used for cons group &2 in hierarchy &1
What causes this issue? The method &V3& was already inherited downwards in hierarchy &V1& for consolidation group &V2&. You w...
GK557
To period &2 is not valid for cons group &1
What causes this issue? <DS:GLOS.consolidation_frequency>Consolidation frequency</> &V3& was specified for consolidation group &a...
Click on this link to search all SAP messages.