Do you have any question about this error?
Message type: E = Error
Message class: GHO_ALLOC_UI - Message Class for UI for Allocation
Message number: 230
Message text: QCI Parameter is not maintained for measurement &1
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
GHO_ALLOC_UI230
- QCI Parameter is not maintained for measurement &1 ?The SAP error message "GHO_ALLOC_UI230 QCI Parameter is not maintained for measurement &1" typically occurs in the context of Quality Inspection (QI) processes within SAP. This error indicates that a required Quality Control Indicator (QCI) parameter has not been set up for a specific measurement.
Cause:
Missing QCI Parameter: The error suggests that the QCI parameter for the specified measurement (indicated by &1) is not maintained in the system. This could be due to:
- The QCI not being defined for the measurement type in the configuration.
- The measurement type not being properly linked to the QCI in the Quality Management (QM) module.
Configuration Issues: There may be issues in the configuration settings related to Quality Management, particularly in the area of inspection plans or characteristics.
Solution:
To resolve this error, you can follow these steps:
Check QCI Configuration:
- Go to the transaction code
SPRO
to access the SAP Customizing Implementation Guide.- Navigate to Quality Management > Quality Inspection > Inspection Planning > Define Quality Control Indicators.
- Ensure that the QCI parameter is defined for the measurement type you are working with.
Maintain QCI for Measurement:
- Use transaction code
QCC1
to maintain the QCI for the specific measurement type.- Ensure that the QCI is correctly assigned to the measurement characteristic.
Review Inspection Plan:
- Check the inspection plan associated with the measurement to ensure that all required characteristics and parameters are correctly defined.
- Use transaction code
QP01
to display or change the inspection plan.Check Master Data:
- Ensure that the material master and any related master data are correctly set up to include the necessary QCI parameters.
Testing:
- After making the necessary changes, test the process again to see if the error persists.
Related Information:
Transaction Codes:
SPRO
: Customizing Implementation GuideQCC1
: Maintain Quality Control IndicatorsQP01
: Create/Change Inspection PlanDocumentation: Refer to SAP Help documentation for Quality Management for detailed information on configuring QCI and inspection plans.
Support: If the issue persists after checking the configuration, consider reaching out to your SAP support team or consulting SAP Notes for any known issues related to this error message.
By following these steps, you should be able to identify and resolve the issue related to the "GHO_ALLOC_UI230 QCI Parameter is not maintained for measurement &1" error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
GHO_ALLOC_UI229
Characteristics &1 is not maintained for &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GHO_ALLOC_UI228
Duplicate Measurement Categories are not allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GHO_ALLOC_UI231
Zonal Contribution is missing at well; maintain at &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GHO_ALLOC_UI232
Theoretical overrides are not allowed for well with TCM as PQ Curve
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.