Do you have any question about this error?
Message type: E = Error
Message class: GG - Messages for FI-SL customizing
Message number: 735
Message text: The name of the table group does not begin with 'Y' or 'Z'.
The name of the table group does not begin with 'Y' or 'Z'. However,
this is a requirement for user-defined table groups.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Enter a table group that begins with 'Y' or 'Z'.
Error message extract from SAP system. Copyright SAP SE.
GG735
- The name of the table group does not begin with 'Y' or 'Z'. ?The SAP error message GG735 indicates that the name of a table group does not begin with 'Y' or 'Z'. In SAP, custom objects (like custom tables, programs, etc.) are typically prefixed with 'Y' or 'Z' to distinguish them from standard SAP objects. This is a part of SAP's naming convention to avoid conflicts and ensure that custom developments are easily identifiable.
Cause:
The error occurs when you attempt to create or modify a table group in SAP, and the name of that table group does not start with 'Y' or 'Z'. This is a restriction imposed by SAP to maintain a clear separation between standard SAP objects and custom developments.
Solution:
To resolve this error, you need to rename the table group to ensure that it starts with either 'Y' or 'Z'. Here are the steps you can follow:
Identify the Table Group: Determine the name of the table group that is causing the error.
Rename the Table Group:
- Go to the relevant transaction in SAP (e.g., SE11 for Data Dictionary).
- Locate the table group that you want to rename.
- Change the name of the table group to start with 'Y' or 'Z'.
- Save your changes.
Check for Dependencies: If the table group is being used in other objects, ensure that you update those references as well.
Transport Changes: If you are working in a development environment, make sure to transport your changes to the appropriate environments (e.g., QA, Production) as needed.
Related Information:
By following these steps, you should be able to resolve the GG735 error and successfully create or modify your table group in SAP.
Get instant SAP help. Start your 7-day free trial now.
GG734
The structure GLU2 has been regenerated
What causes this issue? The internal table GLU2 has been redefined in the repository.System Response The system issues an error message and will not...
GG733
Create the database table for table &
What causes this issue? Table &V1& is transparent. To be able to work with this table, you must create a database table. To do so, call up ...
GG736
Table & already exists
What causes this issue? You want to create table group &V2&. A table in this group is named &V1& in accordance with the naming conve...
GG737
Reference group & is unknown
What causes this issue? You have used &V1& as a reference group. This group is not known in Special Purpose Ledger.System Response The syst...