Message type: E = Error
Message class: GBW - SAP Consolidation interface to BW
Message number: 952
Message text: No path in the Windows-Registry for the Business Explorer Browser
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
The SAP error message GBW952, which states "No path in the Windows-Registry for the Business Explorer Browser," typically occurs when the SAP Business Explorer (BEx) Analyzer is unable to find the necessary registry entries that point to the installation path of the BEx Browser. This can happen due to various reasons, such as improper installation, missing registry entries, or issues with the system configuration.
Cause: Missing Registry Entries: The installation of the BEx Analyzer may not have created the necessary registry entries. Corrupted Installation: The installation of the BEx Analyzer may be corrupted or incomplete. Incorrect Configuration: The system may not be configured correctly to recognize the BEx Browser. User Permissions: Insufficient permissions to access the Windows Registry.
Solution: To resolve the GBW952 error, you can try the following steps: Reinstall BEx Analyzer: Uninstall the current version of the BEx Analyzer. Download the latest version from the SAP Service Marketplace or your organization's software repository. Install the BEx Analyzer again, ensuring
Get instant SAP help. Sign up for our Free Essentials Plan.
GBW951 You have not installed a Windows-Frontend
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GBW950 ----------SEM BCS Menu---------------------------------------------------
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GBW953 Error when calling up a PC application
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
GBW954 No path in the Windows-Registry for the Business Explorer Analyzer
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.