Do you have any question about this error?
Message type: E = Error
Message class: G00 - SAP Consolidation
Message number: 870
Message text: Sequence number &1 already used by char &2
You want to assign sequence no. &V1& for characteristic &V3&. This
sequence number is already used for characteristic &V2&.
Processing terminated
Choose a different sequence number for characteristic &V3&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
G00870
- Sequence number &1 already used by char &2 ?The SAP error message G00870, which states "Sequence number &1 already used by char &2," typically occurs in the context of handling characteristics in SAP, particularly in the areas of variant configuration or classification. This error indicates that the sequence number you are trying to assign to a characteristic is already in use by another characteristic.
Cause:
- Duplicate Sequence Number: The sequence number you are trying to assign to a characteristic is already assigned to another characteristic in the same context (e.g., within the same class or configuration).
- Data Entry Error: There may have been a mistake in data entry where the same sequence number was inadvertently assigned to multiple characteristics.
- Configuration Issues: If you are working with variant configuration, there may be issues with how characteristics are defined or linked.
Solution:
- Check Existing Characteristics: Review the characteristics in the relevant class or configuration to identify which characteristic is currently using the sequence number you are trying to assign. You can do this by navigating to the classification view in SAP.
- Change Sequence Number: If you find that the sequence number is indeed in use, you will need to assign a different, unique sequence number to the characteristic you are trying to create or modify.
- Delete or Modify Existing Characteristic: If the existing characteristic using the sequence number is no longer needed, you may consider deleting it or modifying its sequence number to free up the desired number.
- Consult Documentation: If you are unsure about the implications of changing sequence numbers, consult SAP documentation or your organization's SAP guidelines to ensure that you are not disrupting any existing configurations.
Related Information:
CL02
(Change Class) or CL03
(Display Class) to manage characteristics and classes.If the problem persists after following these steps, it may be beneficial to consult with your SAP support team or a technical consultant who can provide more in-depth assistance.
Get instant SAP help. Start your 7-day free trial now.
G00869
Set the subassignment indicator for characteristic &1
What causes this issue? A sequence number can only be assigned for a characteristic if the characteristic is used as a subassignment or an attribute....
G00868
The sequence number will be deleted for characteristic &1
What causes this issue? You want to deselect the subassignment indicator for characteristic &V2&. This also deselects the subassignment indic...
G00871
Assign a sequence number for char &1
What causes this issue? You selected characteristic &V1& as a subassignment. A sequence number must be assigned to determine the sequence in ...
G00872
Dependent characteristic &1 has a lower sequence number than &2
What causes this issue? The sequence number for characteristic &V1& is too small. This is because the independent characteristic in the compo...
Click on this link to search all SAP messages.