Message text: No aspect has been assigned to the sender structure '&1'
The settings for reading the transaction data in EC-EIS are incomplete.
Termination
Allocate the <DS:SIMG.SIMG_CFMENUOKCMOKCC>Sender structure</> '&V1&' a
an aspect that is suitable for consolidation data. Specify the DDIC
structure 'FC07EIS'.
Error message extract from SAP system. Copyright SAP SE.
G0701
- No aspect has been assigned to the sender structure '&1' ?The SAP error message G0701, which states "No aspect has been assigned to the sender structure '&1'," typically occurs in the context of SAP's data transfer processes, particularly when working with the Data Transfer Workbench (DTW) or when configuring data structures in SAP systems.
Cause:
The error indicates that the system is unable to find an aspect (a specific configuration or mapping) that is associated with the sender structure you are trying to use. This can happen due to several reasons:
- Missing Configuration: The sender structure has not been properly configured in the system.
- Incorrect Mapping: The mapping between the sender structure and the target structure is not defined or is incorrect.
- Data Model Changes: Changes in the data model or structure definitions that have not been reflected in the configuration.
- Transport Issues: If the configuration was transported from another system, it may not have been transported correctly.
Solution:
To resolve the G0701 error, you can follow these steps:
Check Configuration:
- Go to the relevant configuration area in SAP (e.g., SPRO) and verify that the sender structure is correctly defined and that an aspect is assigned to it.
- Ensure that the aspect is correctly configured to match the sender structure.
Review Mapping:
- Check the mapping settings between the sender and target structures. Ensure that all necessary mappings are defined and that they are correct.
Update Data Model:
- If there have been recent changes to the data model, ensure that all related configurations are updated accordingly.
Transport Validation:
- If the configuration was transported from another system, validate that the transport was successful and that all necessary objects were included.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on configuring sender structures and aspects.
Debugging:
- If you have access to debugging tools, you can trace the process to identify where the error is occurring and gather more information about the missing aspect.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the G0701 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
G0700
* 700 - 749 Data Transfer EC-CS -> EC-EIS ****************************
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
G0691
Initialization of settings for SAP S/4HANA (test run)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
G0702
DDIC structure for sender structure '&1' either missing or wrong
What causes this issue? The settings for reading the transaction data in EC-EIS are incomplete.System Response TerminationHow to fix this error? As...
G0703
&1 data records can be transferred to EIS
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.