Do you have any question about this error?
Message type: E = Error
Message class: FWTR - Securities Transaction Management
Message number: 823
Message text: Not possible to determine transaction flow type for SEC flow type &1
The transaction flow type belonging to security flow type &V1& could
not be determined.
No conversion can be executed for this flow type.
Choose <DS:SIMG.BEWARTALTZUBEWNEU>Assign Transaction Flow Types to
Securities Flow Types</> in Customizing and assign a transaction flow
type to each relevant securities flow type. Check the settings and
maintain the required entries.
Error message extract from SAP system. Copyright SAP SE.
FWTR823
- Not possible to determine transaction flow type for SEC flow type &1 ?The SAP error message FWTR823 indicates that the system is unable to determine the transaction flow type for a specific SEC (Securities) flow type. This error typically arises in the context of financial transactions, particularly in the area of securities accounting.
Cause:
The error can occur due to several reasons, including:
Missing Configuration: The flow type in question may not be properly configured in the system. This could mean that the necessary mapping between the flow type and the transaction flow type is missing.
Incorrect Flow Type: The flow type specified may not exist or may not be valid for the transaction being processed.
Data Inconsistencies: There may be inconsistencies in the data being processed, such as missing or incorrect entries in the relevant tables.
Authorization Issues: Sometimes, the user may not have the necessary authorizations to access certain flow types or transaction types.
Solution:
To resolve the FWTR823 error, you can take the following steps:
Check Configuration:
- Go to the configuration settings for the flow types in the SAP system. Ensure that the flow type specified in the error message is correctly defined and mapped to a transaction flow type.
- You can check the configuration in the following path:
- SPRO > Financial Accounting > Financial Accounting Global Settings > Document > Document Types > Define Document Types.
Verify Flow Type:
- Ensure that the flow type you are trying to use is valid and exists in the system. You can check this in the relevant transaction codes (e.g., OBYC for automatic postings).
Review Data:
- Check the data being processed for any inconsistencies or missing information. Ensure that all required fields are filled out correctly.
Check Authorizations:
- Verify that the user has the necessary authorizations to perform the transaction related to the flow type in question.
Consult Documentation:
- Review SAP documentation or notes related to the specific flow type and transaction flow type to ensure that you are following the correct procedures.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide specific notes or patches that address the issue.
Related Information:
By following these steps, you should be able to identify the cause of the FWTR823 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
FWTR822
Convert table &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FWTR821
Table &1 not converted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FWTR824
Entry for flow type &1 with +/- sign &2 already exists
What causes this issue? The entry already exists for flow type &V1& with +/- sign &V2&, which you wanted to add using the conversion....
FWTR825
System error when writing table &1, SY-SUBRC = &2
What causes this issue? A system error occurred when writing table &V1&. The system confirmation was &V2& in SY-SUBRC.System Response...
Click on this link to search all SAP messages.