Do you have any question about this error?
Message type: E = Error
Message class: FVD_INV_ACC - Message Class for Investor Contract
Message number: 101
Message text: No flows maintained for application subfunction &1 (table &2)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
FVD_INV_ACC101
- No flows maintained for application subfunction &1 (table &2) ?The SAP error message FVD_INV_ACC101 indicates that there are no flows maintained for a specific application subfunction in the specified table. This error typically occurs in the context of financial transactions, particularly in the area of financial accounting and invoicing.
Cause:
The error can arise due to several reasons:
- Missing Configuration: The application subfunction may not be properly configured in the system. This could mean that the necessary entries in the relevant configuration tables are missing.
- Incorrect Table Entries: The table referenced in the error message may not have the required entries for the specified application subfunction.
- Data Inconsistency: There may be inconsistencies in the data that prevent the system from recognizing the flows for the specified subfunction.
- Custom Development: If there are custom developments or modifications in the system, they may not be aligned with the standard configurations, leading to this error.
Solution:
To resolve the error, you can take the following steps:
Check Configuration:
- Go to the relevant configuration settings in the SAP system (usually in the SPRO transaction).
- Verify that the application subfunction is correctly defined and that all necessary settings are in place.
Review Table Entries:
- Use transaction SE11 or SE16 to check the contents of the table mentioned in the error message.
- Ensure that there are valid entries for the application subfunction in question.
Maintain Missing Entries:
- If you find that entries are missing, you may need to create or maintain them based on your business requirements.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific application subfunction and table to understand the expected configuration and data.
Check for Custom Code:
- If there are custom developments, review the code to ensure it aligns with the standard SAP processes and does not interfere with the expected flows.
Contact SAP Support:
- If the issue persists after checking the configuration and data, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the root cause of the error and implement the necessary corrections to resolve it.
Get instant SAP help. Start your 7-day free trial now.
FVD_INV_ACC100
*** Performance Problems ************************************************
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FVD_INV_ACC066
Exchange rate flows added to planned records due to rounding differences
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FVD_INV_ACC102
Only 1 entry permitted cond. group &1 app. subfunction &2 table &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FVD_INV_ACC103
Assign exactly one flow to condition group &1 and appl. subfunction &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.