Message type: E = Error
Message class: FRMLSCN - RMS-FRM: Data Retrieval for Contribution and Comp.from Spec.
Message number: 024
Message text: No base unit has been specified for nutrient &1
No base unit has been specified in Specification Management for
nutrient &V1& in the property tree.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Specify the base unit for the nutrient in the <ZK>nutrient base unit</>
value assignment type in the property tree in Specification Management.
You have specified the <ZK>nutrient base unit</> value assignment type
using the FRML_ESTCAT_NUTRIENT environment parameter.
Error message extract from SAP system. Copyright SAP SE.
FRMLSCN024
- No base unit has been specified for nutrient &1 ?The SAP error message FRMLSCN024 indicates that there is no base unit specified for a nutrient in the system. This error typically occurs in the context of formula management or when working with nutritional data in SAP, particularly in industries like food and beverage, pharmaceuticals, or cosmetics where nutritional information is critical.
Cause: Missing Base Unit: The nutrient in question has not been assigned a base unit of measure in the system. This could happen if the nutrient was created without specifying a unit or if the unit was deleted or not properly configured.
Configuration Issues: There may be issues in the configuration of the material master or the formula management settings that prevent the base unit from being recognized. Data Entry Errors: During the creation or modification of a nutrient or formula, the base unit may have been inadvertently left blank.
Solution: Check Nutrient Master Data: Navigate to the nutrient master data in SAP. Verify that the
Get instant SAP help. Sign up for our Free Essentials Plan.
FRMLSCN023
No value assignment type exists for nutrient listing
What causes this issue? No value assignment type exists in the <ZK>specification management</> property tree for assigning <ZK>nutr...
FRMLSCN022
No characteristic name exists for nutrient base unit
What causes this issue? No name has been specified for the characteristic in the property tree within the <ZK>nutrient base unit</> value...
FRMLSCN025
Nutrient &1: Unit &2 and reference unit &3 have different dimensions
What causes this issue? Unit &V2& and reference unit &V3& have been specified for nutrient &V1&. These units have different d...
FRMLSCN026
No function module has been specified for the calculation base
What causes this issue? No function module has been specified in Customizing for <ZK>Recipe Management</> for the <ZK>calculation b...
Click on this link to search all SAP messages.