Message type: E = Error
Message class: FRMLMAN - Message Class for Secondary Data Retrieval
Message number: 014
Message text: Specification &2: Value assignment type &1 contains no value
The specification &V2& does not contain a value in the value assignment
type &V1& or does not contain a value with the required
<DS:GLOS.58EFA916E27CD411BA580800060D888B>usage</>.
If the specification &V2& is an input substance, an energy profile, a
process loss, or a storage loss, the system cannot perform the relevant
calculations.
If the specification &V2& is a primary output, this message is for
information purposes only.
If the specification &V2& is an input substance, an energy profile, a
process loss, or a storage loss, add the missing values in the property
tree for the specification.
If the specification &V2& is a primary output, transfer the value if
necessary by choosing the <ZH>Transfer to Specification of Primary
Output</> function.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message FRMLMAN014 indicates that there is an issue with a value assignment type in a specification. Specifically, it means that the value assignment type (denoted as &1) for the specification (denoted as &2) does not contain any values. This can occur in various contexts, such as when working with material specifications, recipes, or other related data in SAP.
Cause: Missing Values: The value assignment type is defined but has not been populated with any values. Incorrect Configuration: The configuration of the value assignment type may be incorrect, leading to it not being linked to any values. Data Entry Error: During data entry, the user may have overlooked entering values for the specified value assignment type. Inconsistent Data: There may be inconsistencies in the data that prevent the value assignment type from being populated correctly.
Solution: Check Value Assignment Type: Go to the specification in question and check the value assignment type to ensure that
Get instant SAP help. Sign up for our Free Essentials Plan.
FRMLMAN012
Locking spec. &1 is not possible; another user is editing it
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FRMLMAN009
Specify a usage for the view &1 in Customizing
What causes this issue? No usage, that is no rating and no validity area, was entered for the view &V1& in Customizing for <LS>Recipe M...
FRMLMAN015
&1: Value assignment type &3 contains more than one instance
What causes this issue? The system read the data in the value assignment type &V2& (&V3&) for the specification &V1& from the...
FRMLMAN016
No data was specified to write a reference
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
Click on this link to search all SAP messages.