How To Fix FRMLDLG180 - Generation is not possible; Error while deleting existing I/O substances


SAP Error Message - Details

  • Message type: E = Error

  • Message class: FRMLDLG - RMS-FRM: Dialog Messages for Formula

  • Message number: 180

  • Message text: Generation is not possible; Error while deleting existing I/O substances

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message FRMLDLG180 - Generation is not possible; Error while deleting existing I/O substances ?

    The SAP error message FRMLDLG180 indicates that there is an issue with the generation of a formula or recipe due to a problem with deleting existing I/O (input/output) substances. This error typically occurs in the context of SAP's Product Lifecycle Management (PLM) or Recipe Management modules, where formulas or recipes are being created or modified.

    Cause:

    The error can be caused by several factors, including:

    1. Existing Dependencies: The I/O substances may have dependencies or references in other recipes, formulas, or production orders that prevent them from being deleted.
    2. Authorization Issues: The user may not have the necessary permissions to delete the substances.
    3. Data Integrity Issues: There may be inconsistencies or issues in the data related to the substances that are preventing their deletion.
    4. Locked Objects: The substances might be locked by another user or process, preventing modifications.

    Solution:

    To resolve the FRMLDLG180 error, you can take the following steps:

    1. Check Dependencies:

      • Review the I/O substances to see if they are being used in other formulas, recipes, or production orders. If they are, you may need to remove those dependencies first.
    2. Review Authorizations:

      • Ensure that you have the necessary authorizations to delete the I/O substances. You may need to contact your SAP security administrator to verify your permissions.
    3. Data Consistency Check:

      • Perform a data consistency check to identify any issues with the substances. You can use transaction codes like SE11 (Data Dictionary) or SE16 (Data Browser) to investigate the underlying tables.
    4. Unlock Objects:

      • If the substances are locked, you can check for any active sessions or processes that might be holding the lock. You can use transaction SM12 to view and manage locks.
    5. Error Logs:

      • Check the application logs for more detailed error messages that might provide additional context. You can use transaction SLG1 to view application logs.
    6. Consult Documentation:

      • Refer to SAP documentation or notes related to the specific error message for any additional troubleshooting steps or patches that may be available.
    7. Contact SAP Support:

      • If the issue persists after trying the above steps, consider reaching out to SAP support for further assistance.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as:

      • C201: Create Recipe
      • C202: Change Recipe
      • C203: Display Recipe
      • C223: Change Formula
      • C224: Display Formula
    • SAP Notes: Search for SAP Notes related to FRMLDLG180 for any known issues or fixes.

    • User Forums: Engage with SAP community forums or user groups where similar issues may have been discussed.

    By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
The AI Support Assistant is great. It provides comprehensive assistance even on the most difficult issues. I highly recommend this service.
Rate 1
John Jordan
SAP Consultant & Author