Message type: E = Error
Message class: FRMLCALC - Formula Calculations
Message number: 048
Message text: Values in following value assignment types are overwritten with zero: &1
The specification data of the stream (primary output) has changed.
The system resets the Consistent indicator in all consistent stage
formulas that are affected by this change.
Call the subsequent stages and save them. The system recalculates the
stages when they are called.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
FRMLCALC048
- Values in following value assignment types are overwritten with zero: &1 ?The SAP error message FRMLCALC048 indicates that during a calculation or processing of a formula, certain value assignment types are being overwritten with zero. This typically occurs in the context of SAP's formula calculation framework, which is often used in areas like product costing, material requirements planning, or other scenarios where formulas are applied to derive values based on certain inputs.
Cause: The error can be caused by several factors, including: Missing or Incorrect Data: The value assignment types referenced in the error message may not have valid data or may be missing entirely. This can happen if the relevant master data or transaction data is not maintained correctly. Formula Logic Issues: The formula itself may have logic that leads to the overwriting of values. For example, if there are conditions in the formula that are not met, it may default to zero.
Configuration Issues: There may be configuration settings in the formula calculation framework
Get instant SAP help. Sign up for our Free Essentials Plan.
FRMLCALC047
Stream in formula &3: Conversion from &1 to &2 is not possible
What causes this issue? The system attempted to convert two units of measure to each other for a stream item. For this conversion, it uses properties...
FRMLCALC046
Formula is not consistent
What causes this issue? The current formula contains faulty data.System Response The consistency check failed.How to fix this error? Check the appl...
FRMLCALC049
Subsequent stages were recalculated successfully
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FRMLCALC050
Stream in formula &3 has no composition
What causes this issue? The formula &V3& contains a stream that has no further explosion in this context. As this type of stream cannot be sa...
Click on this link to search all SAP messages.