Do you have any question about this error?
Message type: E = Error
Message class: FRMLAPI - RMS-FRM: API Messages for Formula
Message number: 259
Message text: Explosion is single-level
In Customizing for <LS>Recipe Management</>, you have specified for the
explosion scope that the system performs the explosion only for the
initial formula and then uses data from a specific formula view. The
explosion is therefore single-level.
The formula explosion determines the formulas for the input components
of the initial formula in which the input components are outputs, and
transfers to the explosion result the data from these formulas that you
entered in the relevant views. The formulas found are not exploded
further.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
FRMLAPI259
- Explosion is single-level ?The SAP error message FRMLAPI259, which states "Explosion is single-level," typically occurs in the context of Bill of Materials (BOM) processing or when working with formulas in SAP. This error indicates that the system is attempting to perform a multi-level explosion of a BOM or formula, but the structure is only defined at a single level.
Cause:
- Single-Level BOM/Formulation: The BOM or formula being processed is defined in such a way that it does not have any sub-components or sub-formulas. This means that the system cannot perform a multi-level explosion because there are no additional levels to explore.
- Incorrect Configuration: The configuration of the BOM or formula may not be set up correctly to allow for multi-level explosions.
- Data Integrity Issues: There may be issues with the data integrity of the BOM or formula, such as missing components or incorrect settings.
Solution:
- Check BOM/Formulation Structure: Review the BOM or formula in question to ensure that it is set up correctly. If it is intended to have sub-components, make sure they are defined properly.
- Define Sub-Components: If the BOM or formula is meant to be multi-level, add the necessary sub-components or sub-formulas to create the desired structure.
- Use Single-Level Explosion: If the single-level explosion is intended, you may need to adjust your process or expectations accordingly. Ensure that you are using the correct transaction or function for single-level processing.
- Review Configuration Settings: Check the configuration settings in SAP related to BOMs and formulas to ensure they are set up to allow for the desired level of explosion.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling BOMs and formulas, as well as troubleshooting common issues.
Related Information:
If the problem persists after following these steps, it may be beneficial to consult with your SAP support team or a technical consultant who can provide more in-depth assistance.
Get instant SAP help. Start your 7-day free trial now.
FRMLAPI258
Explosion is not possible; quantity of formula &2 is 0
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FRMLAPI257
C++ solver returned internal error code; see long text
What causes this issue? INCLUDE RMS_FRM_CALC_API_GEN OBJECT DOKU ID TX The C++ solver for calculating the explosion has triggered an internal error c...
FRMLAPI270
Component type is not defined for explosion; &1 &2 &3 &4
What causes this issue? The component type specified for the component is not defined for the explosion scope. This means no entry exists in Customiz...
FRMLAPI271
Comp. is not exploded; comp. type is not rel. for explosion; &1 &2 &3 &4
What causes this issue? It was specified in Customizing for <ZK>Recipe Management</> that the component type of the component is not rele...
Click on this link to search all SAP messages.