Message type: E = Error
Message class: FL - Function Builder messages
Message number: 383
Message text: With RFC modules, no generic types are allowed
You attempted to assign a generic type to a parameter of a remotely
called function module. This is not supported.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
You must assign either a reference field or a reference structure to
each function parameter.
Error message extract from SAP system. Copyright SAP SE.
FL383
- With RFC modules, no generic types are allowed ?The SAP error message FL383 ("With RFC modules, no generic types are allowed") typically occurs when you are trying to use a generic data type in a Remote Function Call (RFC) module. RFC modules have specific requirements regarding data types, and generic types are not permitted in this context.
Cause: The error arises when: You define a parameter in an RFC-enabled function module with a generic type (like ANY, TABLE, or STRING). The RFC interface cannot handle these generic types because they do not have a specific structure or format that can be serialized and transmitted over the network.
Solution: To resolve this error, you should: Change Generic Types to Specific Types: Review the parameters of your RFC-enabled function module and replace any generic types with specific types. For example: Instead of using STRING, use CHAR or VARCHAR with a defined length. Instead of using TABLE, define a specific structure for the table. Define Structures: If you need to pass
Get instant SAP help. Sign up for our Free Essentials Plan.
FL382
All parameters in RFC require a reference field or reference type
What causes this issue? You have defined a parameter without a reference field or a type.in a remotely called function module. This is not supported....
FL381
In RFC modules, only parameters with pass by value are allowed
What causes this issue? You have defined a reference parameter for a remotely called function module. However, only value parameters are allowed in t...
FL384
No CHANGING parameters allowed with RFC
What causes this issue? You attempted to create a CHANGING parameter for a remotely called function module. However, remotely called function modules...
FL385
Type &1 is not known or allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.