Do you have any question about this error?
Message type: E = Error
Message class: FKK_BRF - BRF in FICA
Message number: 017
Message text: No buffer element with structure ID &1
There is no buffer element with structure ID &V1&. Buffer elements are
either provided by the application that calls the <LS>Business Rules
Framework</>, or they must be initialized in an action.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Initialize the buffer element, or use a different structure ID.
Error message extract from SAP system. Copyright SAP SE.
FKK_BRF017
- No buffer element with structure ID &1 ?The SAP error message FKK_BRF017 with the description "No buffer element with structure ID &1" typically occurs in the context of the SAP Convergent Charging (SAP CC) or SAP Contract Accounts Receivable and Payable (SAP FI-CA) modules. This error indicates that the system is trying to access a buffer element that does not exist for the specified structure ID.
Cause:
- Missing Configuration: The structure ID referenced in the error message may not be properly configured in the system. This could be due to missing entries in the relevant tables or incorrect settings in the configuration.
- Data Inconsistency: There may be inconsistencies in the data that lead to the system not being able to find the expected buffer element.
- Custom Development: If there are custom developments or enhancements in the system, they might not be handling the buffer elements correctly, leading to this error.
- Transport Issues: If the system has recently undergone a transport of changes, it is possible that the necessary buffer elements were not transported correctly.
Solution:
- Check Configuration: Verify the configuration settings related to the structure ID mentioned in the error message. Ensure that all necessary entries are present and correctly configured.
- Review Custom Code: If there are any custom developments, review the code to ensure that it is correctly handling the buffer elements and structure IDs.
- Data Consistency Check: Perform a data consistency check to identify any inconsistencies that may be causing the issue. This may involve checking related tables and entries.
- Recreate Buffer Elements: If applicable, try to recreate the buffer elements for the structure ID in question. This may involve running specific transactions or programs that regenerate the necessary data.
- Consult SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates that resolve the issue.
- Contact SAP Support: If the issue persists after trying the above solutions, consider reaching out to SAP Support for further assistance. Provide them with the error details and any relevant logs or screenshots.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
FKK_BRF016
Structure ID &1 is already being used
What causes this issue? You are trying to initialize a buffer element with a structure ID that is already in use.System Response The system issues a...
FKK_BRF015
Enter an expression
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FKK_BRF018
Enter an index or a type of aggregation
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FKK_BRF019
No value defined in context for expression &1
What causes this issue? The expression &V1&, selected by structure/table &V2& in the context does not return a value. In the expressi...
Click on this link to search all SAP messages.