Do you have any question about this error?
Message type: E = Error
Message class: FDT_CORE - Formula & Derivation Tool: Core
Message number: 884
Message text: Invalid state of switch in line &1 (only "X" and " " are possible values)
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
FDT_CORE884
- Invalid state of switch in line &1 (only "X" and " " are possible values) ?The SAP error message FDT_CORE884 indicates that there is an issue with the state of a switch in the context of a field or data element. The message specifies that the only valid values for this switch are "X" (which typically indicates an active or enabled state) and a blank space (which usually indicates an inactive or disabled state).
Cause:
The error occurs when the system encounters a value for the switch that is neither "X" nor a blank space. This could happen due to:
- Incorrect Configuration: The switch might have been set to an invalid value during configuration or customization.
- Data Corruption: There may be corrupted data in the database that is causing the switch to have an unexpected value.
- Programming Error: A custom program or enhancement might be incorrectly setting the value of the switch.
Solution:
To resolve the error, you can take the following steps:
Check Configuration: Review the configuration settings related to the switch in question. Ensure that it is set to either "X" or blank. You may need to consult the relevant documentation or configuration guides.
Data Validation: If the switch is part of a data record, check the data in the database to ensure that it does not contain any invalid values. You can use transaction codes like SE16 or SE11 to inspect the relevant tables.
Debugging: If the error is occurring in a custom program or enhancement, use the ABAP debugger to trace the execution and identify where the invalid value is being set. Correct the logic to ensure that only valid values are assigned to the switch.
Consult SAP Notes: Check the SAP Support Portal for any relevant notes or patches that might address this specific error. There may be known issues or updates that can resolve the problem.
Testing: After making changes, thoroughly test the affected functionality to ensure that the error no longer occurs and that the system behaves as expected.
Related Information:
By following these steps, you should be able to identify the root cause of the FDT_CORE884 error and implement an appropriate solution.
Get instant SAP help. Start your 7-day free trial now.
FDT_CORE883
Either provide rule or ruleset exit but not both (position &1)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE882
Missing condition for ruleset exit (position &1)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE885
Invalid time stamps in line &1; to-value &2 smaller / equal from-value &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE886
No rule provided at position &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.