Do you have any question about this error?
Message type: E = Error
Message class: FDT_CORE - Formula & Derivation Tool: Core
Message number: 444
Message text: Component &1 of DDIC structure &2 not bound: switch &3 (&4) is on
For the current structure, the system has detected the following status:
By the time the binding has been established between the current
structure and the DDIC structure, component &v1& has not been available
due to the setting of switch &v3&.
In the meantime, the switch has been turned on so that component &v1& is
now available in the bound DDIC structure &v2&.
You can use the structure, but you don't have access to component &v1&
that is now available in the bound DDIC structure &v2&.
If you want the current structure to reflect all the components that are
currently available in DDIC structure &v2&, refresh the binding.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
FDT_CORE444
- Component &1 of DDIC structure &2 not bound: switch &3 (&4) is on ?The SAP error message FDT_CORE444 indicates that there is an issue with a component of a Data Dictionary (DDIC) structure that is not bound due to a specific switch being activated. This error typically arises in the context of using the SAP Fiori or SAP UI5 applications, particularly when dealing with data binding in the context of the Fiori Elements or Smart Controls.
Cause:
The error message can be broken down into several components:
- Component &1: This refers to the specific component of the DDIC structure that is causing the issue.
- DDIC structure &2: This is the name of the Data Dictionary structure that contains the problematic component.
- Switch &3: This indicates a specific configuration switch that is currently active, which is preventing the binding of the component.
- (&4): This may provide additional context or details about the switch or the error.
The root cause of this error is typically related to:
To resolve the FDT_CORE444 error, you can take the following steps:
Check the Switch: Identify the switch mentioned in the error message. You can do this by checking the relevant configuration settings in the SAP system. The switch may be related to specific features or functionalities that need to be enabled for the component to bind correctly.
Modify the Switch Settings: If the switch is indeed causing the issue, you may need to change its status. This can typically be done through transaction codes like SFW5
(Switch Framework) or SFW2
(Switch Framework - Switches) in the SAP GUI. Ensure that the switch is set to the appropriate status that allows for the binding of the component.
Review the DDIC Structure: Ensure that the DDIC structure and its components are correctly defined. Check for any inconsistencies or missing definitions that could lead to binding issues.
Check for Dependencies: Sometimes, other components or structures may have dependencies that affect the binding. Ensure that all related components are correctly configured.
Consult Documentation: If you are unsure about the specific switch or its implications, refer to SAP documentation or consult with your SAP Basis or development team for guidance.
Testing: After making changes, test the application or functionality again to ensure that the error has been resolved.
By following these steps, you should be able to identify the cause of the FDT_CORE444 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
FDT_CORE442
Default object types are not included in the Filter
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE441
Unknown object type &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE445
Component &1 of DDIC structure &2 not bound: switch &3 (&4) is off
What causes this issue? You have established a binding relationship between the current structure data object and DDIC structure &v2&. The sy...
FDT_CORE446
Component &1 of DDIC structure &2 is controlled by switch &3 (&4)
What causes this issue? The system has detected that in the bound DDIC structure &v2&, the availability of component &v1& is controll...
Click on this link to search all SAP messages.