Do you have any question about this error?
Message type: E = Error
Message class: FDT_CORE - Formula & Derivation Tool: Core
Message number: 390
Message text: Invalid recursion: &1 holds a reference to itself
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
FDT_CORE390
- Invalid recursion: &1 holds a reference to itself ?The SAP error message FDT_CORE390: Invalid recursion: &1 holds a reference to itself typically occurs in the context of the SAP Form Data Tool (FDT) or when working with Adobe Forms in SAP. This error indicates that there is a recursive reference in the data structure or form definition, meaning that an object is referencing itself directly or indirectly, which is not allowed.
Cause:
- Self-Referencing Structure: The most common cause of this error is that a field or node in the data structure is set to reference itself. This can happen if you have defined a field that points to itself in a way that creates a loop.
- Incorrect Data Binding: If you are binding data elements incorrectly in the form, it can lead to a situation where the form tries to access a field that references itself.
- Form Logic Issues: If there are scripts or logic in the form that inadvertently create a recursive call or reference, this can trigger the error.
Solution:
- Check Data Structure: Review the data structure or the context in which the error occurs. Ensure that no field is referencing itself directly or indirectly.
- Review Form Bindings: Go through the bindings of the form fields and ensure that they are correctly set up. Make sure that no field is bound to itself.
- Debug Scripts: If there are any scripts or calculations in the form, check them for any logic that might cause a recursive reference. Modify the logic to prevent self-referencing.
- Test Changes: After making changes, test the form again to see if the error persists. If it does, continue to investigate other areas where recursion might be occurring.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the FDT_CORE390 error in your SAP environment.
Get instant SAP help. Start your 7-day free trial now.
FDT_CORE389
Text &1 is not convertible into a boolean.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE388
Domain values may not be unique (see value table &1 in DDIC)
What causes this issue? The current data object is bound to a data element in the ABAP Dictionary (DDIC). The system has determined that the bound da...
FDT_CORE391
Invalid recursion: &1 uses &2 uses &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
FDT_CORE392
Invalid recursion: &1 uses &2 uses &3 uses &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.