Do you have any question about this error?
Message type: E = Error
Message class: EZ - Print workbench
Message number: 155
Message text: Name of start/end exit &1 is invalid
For organizational purposes the name of the generated function group
must end with the number of the current client. This is necessary if
you are working with application forms with the same name in different
clients.
You are required to enter an appropriate name.
Enter a name that ends with the current client number.
Error message extract from SAP system. Copyright SAP SE.
EZ155
- Name of start/end exit &1 is invalid ?The SAP error message EZ155, which states "Name of start/end exit &1 is invalid," typically occurs when there is an issue with the naming convention or the configuration of a start or end exit in the SAP system. This error can arise in various contexts, such as during the execution of a program or when configuring enhancements.
Cause:
- Invalid Naming Convention: The name provided for the start or end exit does not conform to the required naming conventions set by SAP. This could include issues such as incorrect characters, length, or format.
- Non-Existent Exit: The specified exit does not exist in the system, either because it has not been created or has been deleted.
- Configuration Issues: There may be issues in the configuration settings related to the exit, such as incorrect parameters or settings in the enhancement framework.
- Transport Issues: If the exit was recently transported from another system, there may have been issues during the transport process that led to the exit not being properly registered.
Solution:
- Check Naming Conventions: Ensure that the name of the start or end exit follows the SAP naming conventions. Typically, it should start with a letter and can include letters, numbers, and underscores.
- Verify Existence: Check if the exit actually exists in the system. You can do this by navigating to the relevant transaction (e.g., SE80 or SE11) and searching for the exit.
- Review Configuration: Go through the configuration settings related to the exit. Ensure that all parameters are correctly set and that there are no missing entries.
- Transport Check: If the exit was recently transported, check the transport logs for any errors. You may need to re-transport the exit or manually create it in the target system.
- Consult Documentation: Refer to SAP documentation or notes related to the specific exit you are working with for any additional requirements or constraints.
Related Information:
If the problem persists after following these steps, consider reaching out to your SAP Basis or development team for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EZ153
Application form &1 was renamed as &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EZ152
SAPscript form &1 does not exist in language &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
EZ156
Application form &1 cannot be printed; it is not active
trados = docu -> fi -> fica -> fica.tmwWhat causes this issue? The application form &V1& is not active and therefore cannot be prin...
EZ160
Enter a target language different to the original language
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.